EliteCore Full Core Biopsy Device. EliteCore 18G, 20cm with and without HiLiter tip, 15 cm with and without...

Stryker Corp. / initiated 2015-04-24 / Terminated / root cause: design

Stryker Instruments Div. of Stryker Corporation began a recall of EliteCore Full Core Biopsy Device. EliteCore 18G, 20cm with and without HiLiter tip, 15 cm with and without HiLiter tip, and 10 cm with and without HiLiter tip on . FDA classified it as Class II and gives the reason as "Potential for the device cannula to overthrow past the intended length". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-1671-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Stryker Corp.
Product
EliteCore Full Core Biopsy Device. EliteCore 18G, 20cm with and without HiLiter tip, 15 cm with and without HiLiter tip, and 10 cm with and without HiLiter tip.
Product code
KNW Instrument, Biopsy
Reason for recall
Potential for the device cannula to overthrow past the intended length.
Root cause tag
design
FDA root cause
Device Design
Action
Stryker sent an Urgent Medical Device Recall Notification letter dated May 5, 2015, to all affected customers via Fed Ex overnight. Customers were instructed to qaurantine any product found, return the repsonse form even if there is no product on hand, forward the letter if further distribution of recalled product occurred, return recalled product to Stryker. Customers were instructed to 269-389-2458 with any questions.
Quantity in commerce
1,420 Units
Distribution
US Nationwide Distribution including AL, AR, AZ, CA, CO, FL, GA, IL, IN, KS, KY, LA, MI, MN, MO, MS, NJ, NM, NV, NY, OK, OR, PA, TN, TX, UT, VA, and WI.
Product codes and lots
Stryker Product Numbers: 0915-820-000; 0905-820-000; 0915-815-000; 0905-815-000; 0915-810-000; 0905-810-000; RLS Product Numbers: 931018, 931518, 941518.  Stryker lot numbers distributed 16-JUN-2014 to 10-FEB-2015 affected: 61406001, 61406002, 61406007  RLS lot numbers distributed 28-MAR-2013 to 16-JUN-2014 affected: 61302001, 61203001, 61108001, 61208002, 61309001

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1671-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1671-2015Class IITerminatedVoluntary: Firm initiated