Z-1671-2015Class II
EliteCore Full Core Biopsy Device. EliteCore 18G, 20cm with and without HiLiter tip, 15 cm with and without...
Stryker Corp. / initiated 2015-04-24 / Terminated / root cause: design
Stryker Instruments Div. of Stryker Corporation began a recall of EliteCore Full Core Biopsy Device. EliteCore 18G, 20cm with and without HiLiter tip, 15 cm with and without HiLiter tip, and 10 cm with and without HiLiter tip on . FDA classified it as Class II and gives the reason as "Potential for the device cannula to overthrow past the intended length". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-1671-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Stryker Corp.
- Product
- EliteCore Full Core Biopsy Device. EliteCore 18G, 20cm with and without HiLiter tip, 15 cm with and without HiLiter tip, and 10 cm with and without HiLiter tip.
- Product code
- KNW Instrument, Biopsy
- Reason for recall
- Potential for the device cannula to overthrow past the intended length.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Stryker sent an Urgent Medical Device Recall Notification letter dated May 5, 2015, to all affected customers via Fed Ex overnight. Customers were instructed to qaurantine any product found, return the repsonse form even if there is no product on hand, forward the letter if further distribution of recalled product occurred, return recalled product to Stryker. Customers were instructed to 269-389-2458 with any questions.
- Quantity in commerce
- 1,420 Units
- Distribution
- US Nationwide Distribution including AL, AR, AZ, CA, CO, FL, GA, IL, IN, KS, KY, LA, MI, MN, MO, MS, NJ, NM, NV, NY, OK, OR, PA, TN, TX, UT, VA, and WI.
- Product codes and lots
- Stryker Product Numbers: 0915-820-000; 0905-820-000; 0915-815-000; 0905-815-000; 0915-810-000; 0905-810-000; RLS Product Numbers: 931018, 931518, 941518. Stryker lot numbers distributed 16-JUN-2014 to 10-FEB-2015 affected: 61406001, 61406002, 61406007 RLS lot numbers distributed 28-MAR-2013 to 16-JUN-2014 affected: 61302001, 61203001, 61108001, 61208002, 61309001
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1671-2015 | Class II | Terminated | Voluntary: Firm initiated |