Z-1917-2015Class II

HeartWare Ventricular Assist System (HVAD) For use as a bridge-to-cardiac transplantation in patient who are...

HeartWare, Inc. / initiated 2015-04-29 / Open, Classified / root cause: software

HeartWare Inc began a recall of HeartWare Ventricular Assist System (HVAD) For use as a bridge-to-cardiac transplantation in patient who are at risk of death from refractory end-stage left... on . FDA classified it as Class II and gives the reason as "Complaints with the HVAD Abnormal Power Source Switching". As of , the recall status on record is Open, Classified, and MDM tags the root cause as software.

Recall record

Recall number
Z-1917-2015
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
HeartWare, Inc.
Product
HeartWare Ventricular Assist System (HVAD) For use as a bridge-to-cardiac transplantation in patient who are at risk of death from refractory end-stage left ventricular heart failure.
Product code
DSQ Ventricular (Assist) Bypass
Reason for recall
Complaints with the HVAD Abnormal Power Source Switching.
Root cause tag
software
FDA root cause
Software design
Action
HeartWare sent an Urgent Medical Device Correction letter to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to review the enclosed Patient Communication and familiarize the contents, forward the notice to those individuals withing their organization who need to be aware of its contents, identify their patients currently supported by the HVAD System, distribute the Patient Communication to their patients via FedEX or some other reliable means of communication. Customers with questions were instructed to contact their HeartWare representative should they need any assistance with the process. Customers were asked to complete, sign, and return the Acknowledgement and Completion Form to HeartWare. Customers with quesitons were instructed to call 1-888-494-6365.
Quantity in commerce
3,747 currently in use.
Distribution
US including AL, AZ, CA, CO, CT, DC, DE, FL, GA, IA, IL, IN, KY, LA, MA, MD, MI, MN, MO, MS, NC, NH, NJ, NY, OH, OR, PA, SC, TN, TX, UT, VA and Internationally to Argentina, Australia, Austria, Belgium, Brazil, Canada, Chile, Croatia, Czech Republic, Denmark, Egypt, Finland, France, Germany, Greece, Hong Kong, Hungary, India, Israel, Italy, Japan, Korea, Lebanon, Lithuania, Luxemburg, Malaysia, Netherlands, New Zealand, Norway, Poland, Romania, Singapore, Slovakia, South Africa, Spain, Sweden, Switzerland, Turkey, and UK.
Product codes and lots
Catalog #'s US: 1101 and 1103 / OUS: 1100,1101,1102,1104,1104JP and 1205. Serial #: ALL HeartWare HVAD systems currently in use.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1917-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1917-2015Class IIOngoingVoluntary: Firm initiated