Z-1729-2015Class II

Assay Data Disk (ADD), All DRV versions that support product within expiry dating Automates pre-analytical...

Ortho-Clinical Diagnostics, Inc. / initiated 2015-04-06 / Terminated / root cause: software

Ortho-Clinical Diagnostics began a recall of Assay Data Disk (ADD), All DRV versions that support product within expiry dating Automates pre-analytical and post-analytical sample and data management for... on . FDA classified it as Class II and gives the reason as "Software anomaly regarding urine samples that require acidified pretreatment. The software has allowed urine samples for assays that require acidified pretreatment to be metered from the same sample container as assays...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-1729-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Ortho-Clinical Diagnostics, Inc.
Product
Assay Data Disk (ADD), All DRV versions that support product within expiry dating Automates pre-analytical and post-analytical sample and data management for in vitro diagnostic use. VITROS Urine Assays: VITROS Calcium (Ca), Magnesium (Mg), and Phosphorus (Phos) requires acidification pretreatment prior to urine assay testing
Product code
JJE Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
Reason for recall
Software anomaly regarding urine samples that require acidified pretreatment. The software has allowed urine samples for assays that require acidified pretreatment to be metered from the same sample container as assays that required no pretreatment when the sample was programmed.
Root cause tag
software
FDA root cause
Software design
Action
Ortho Clinical Diagnostics distributed correction notification letters dated April 6, 2015, and response forms to their customers via courier service. All urine patient results that require pretreatment was advised to refer to the notice of correction for instructions. Correction notices should also be posted beside the device user documentation for easy reference. Customers were advised to complete and return the Confirmation of Receipt before April 20, 2015. Customers with questions may contact the Customer Technical Service at 1- 800-421-3311 anytime.
Quantity in commerce
2,387 units Total (987 domestically & 1400 internationally)
Distribution
Worldwide Distribution - US Nationwide, Brazil, Chile, Mexico, Australia, Hong Kong, India, Taiwan, Belgium, Denmark, France, Ireland, Italy, Portugal, Romania, Spain, Sweden and the UK.
Product codes and lots
Product Code: 6801876 Unique Device Identifier Numbers: 10758750001576

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1729-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1728-2015Class IITerminatedVoluntary: Firm initiated
Z-1729-2015Class IITerminatedVoluntary: Firm initiated