Z-1812-2015Class II

Thoracic Grasper, 5 MM, for use with da Vinci S (IS2000) and SI (IS3000) Surgical Systems. Intended for...

Intuitive Surgical, Inc. / initiated 2015-05-21 / Terminated / root cause: manufacturing process

Intuitive Surgical, Inc. began a recall of Thoracic Grasper, 5 MM, for use with da Vinci S (IS2000) and SI (IS3000) Surgical Systems. Intended for endoscopic manipulation of tissue, including grasping on . FDA classified it as Class II and gives the reason as "The coating of the 5 mm Thoracic Grasper main tube may experience damage with the possibility of fragments of coating material dislodging and potentially falling into patient". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-1812-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Intuitive Surgical, Inc.
Product
Thoracic Grasper, 5 MM, for use with da Vinci S (IS2000) and SI (IS3000) Surgical Systems. Intended for endoscopic manipulation of tissue, including grasping.
Product code
NAY System, Surgical, Computer Controlled Instrument
Reason for recall
The coating of the 5 mm Thoracic Grasper main tube may experience damage with the possibility of fragments of coating material dislodging and potentially falling into patient.
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
Urgent Medical Device Recall letters were sent to all consignees on May 21, 2015. The letter describes the affected product and issue involved. Additionally, the risk to health, as well as the actions to be taken were also discussed in the letter. Customers are to ensure that all affected personnel were informed of the notice. All affected product are to be identified and returned by contacting Customer Service for a RMA. The Acknowledgment Form is to be completed and returned using the instructions provided. If further information or support concerning this recall is needed, customers are to contact their local Clinical Sales Representative or Intuitive Surgical Customer Service.
Quantity in commerce
2,436 units
Distribution
Worldwide Distribution -- US, Belgium, Brazil, Canada, Chile, Colombia,, Denmark, France, Germany, India, Netherlands, Panama, Singapore, South Korea, Switzerland, Taiwan, Turkey, and United Kingdom.
Product codes and lots
version 420343-01 and 420323-02, all lots

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1812-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1812-2015Class IITerminatedVoluntary: Firm initiated