Z-2125-2015Class II
WIZARD2 2-detector, 550 samples
Revvity Health Sciences, Inc. / initiated 2015-06-03 / Terminated / root cause: manufacturing process
Perkinelmer began a recall of WIZARD2 2-detector, 550 samples Product Code: 2470-0020 The Wizard" gamma counter is intended to detect and count gamma radiation emitted by clinical samples on . FDA classified it as Class II and gives the reason as "Error in WIZARD2 Barcode ID Label #023 Content may produce erroneous results". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-2125-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Revvity Health Sciences, Inc.
- Product
- WIZARD2 2-detector, 550 samples Product Code: 2470-0020 The Wizard" gamma counter is intended to detect and count gamma radiation emitted by clinical samples.
- Product code
- JJJ Counter (Beta, Gamma) For Clinical Use
- Reason for recall
- Error in WIZARD2 Barcode ID Label #023 Content may produce erroneous results
- Root cause tag
- manufacturing process
- FDA root cause
- Nonconforming Material/Component
- Action
- Perkin Elmer issued the recall letter on June 3, 2015. Action to be taken: Until the PerkinElmer correction has been completed, we request you immediately destroy all barcode ID labels #023 in your possession. The WIZARD Gamma Counter barcode label binder contains a total of 20 barcode labels identified as #023 (i.e. 2 labels on each of 10 pages). Please ensure you remove the barcode labels ID #023 from all barcode label binders in your possession. Please be sure to inspect all sample racks to remove and destroy any barcode ID labels #023 already affixed to racks. A WIZARD2 Gamma Counter barcode label binder with corrected barcode labels ID #023 will be provided upon request and return of the completed Correction Response Form to PerkinElmer. Correction Response Form and return it by scan and e-mail to [email protected]
- Quantity in commerce
- 53 units
- Distribution
- Worldwide Distribution-US (nationwide) and the countries of ARGENTINA AUSTRALIA AUSTRIA BELGIUM BRAZIL CANADA CHILE CHINA COSTA RICA CROATIA CZECH REPUBLIC DENMARK ETHIOPIA FINLAND FRANCE GERMANY GREECE HONG KONG HUNGARY INDIA IRELAND ISRAEL ITALY JAPAN KOREA KUWAIT LUXEMBOURG MEXICO MYANMAR NETHERLANDS NORWAY PHILIPPINES POLAND REUNION SAUDIA ARABIA SINGAPORE SOUTH AFRICA SPAIN SWEDEN SWITZERLAND TAIWAN THAILAND TURKEY UK.
- Product codes and lots
- Serial Numbers: DG01130042 DG01130083 DG01130122 DG02130179 DG03130196 DG03130242 DG04130300 DG04130318 DG05129208 DG05129239 DG05129251 DG05130343 DG06129284 DG06129320 DG07129407 DG07129433 DG08118247 DG08129522 DG08129575 DG09129612 DG09129619 DG09129643 DG10129707 DG10129728 DG10129768 DG11129836 DG11129838 DG12120004 DG12120038 SGWZ03150235 SGWZ04140103 SGWZ07140107 SGWZ07140108 SGWZ14140125 SGWZ16140131 SGWZ16140134 SGWZ20140150 SGWZ21140152 SGWZ27130022 SGWZ28140168 SGWZ29130026 SGWZ32130030 SGWZ33140183 SGWZ35140188 SGWZ36130039 SGWZ37130044 SGWZ39130048 SGWZ42130051 SGWZ43130053 SGWZ43130056 SGWZ44130057 SGWZ45130062 SGWZ47130076
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2124-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2125-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2126-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2127-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2128-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2129-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2130-2015 | Class II | Terminated | Voluntary: Firm initiated |