Perkin Elmer WIZARD2 10-detector, 550 samples

Revvity Health Sciences, Inc. / initiated 2015-06-03 / Terminated / root cause: manufacturing process

Perkinelmer began a recall of Perkin Elmer WIZARD2 10-detector, 550 samples Product Code: 2470-0100, 3470-0100 The Wizard" gamma counter is intended to detect and count gamma radiation... on . FDA classified it as Class II and gives the reason as "Error in WIZARD2 Barcode ID Label #023 Content may produce erroneous results". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2127-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Revvity Health Sciences, Inc.
Product
Perkin Elmer WIZARD2 10-detector, 550 samples Product Code: 2470-0100, 3470-0100 The Wizard" gamma counter is intended to detect and count gamma radiation emitted by clinical samples.
Product code
JJJ Counter (Beta, Gamma) For Clinical Use
Reason for recall
Error in WIZARD2 Barcode ID Label #023 Content may produce erroneous results
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
Perkin Elmer issued the recall letter on June 3, 2015. Action to be taken: Until the PerkinElmer correction has been completed, we request you immediately destroy all barcode ID labels #023 in your possession. The WIZARD Gamma Counter barcode label binder contains a total of 20 barcode labels identified as #023 (i.e. 2 labels on each of 10 pages). Please ensure you remove the barcode labels ID #023 from all barcode label binders in your possession. Please be sure to inspect all sample racks to remove and destroy any barcode ID labels #023 already affixed to racks. A WIZARD2 Gamma Counter barcode label binder with corrected barcode labels ID #023 will be provided upon request and return of the completed Correction Response Form to PerkinElmer. Correction Response Form and return it by scan and e-mail to [email protected]
Quantity in commerce
54 units
Distribution
Worldwide Distribution-US (nationwide) and the countries of ARGENTINA AUSTRALIA AUSTRIA BELGIUM BRAZIL CANADA CHILE CHINA COSTA RICA CROATIA CZECH REPUBLIC DENMARK ETHIOPIA FINLAND FRANCE GERMANY GREECE HONG KONG HUNGARY INDIA IRELAND ISRAEL ITALY JAPAN KOREA KUWAIT LUXEMBOURG MEXICO MYANMAR NETHERLANDS NORWAY PHILIPPINES POLAND REUNION SAUDIA ARABIA SINGAPORE SOUTH AFRICA SPAIN SWEDEN SWITZERLAND TAIWAN THAILAND TURKEY UK.
Product codes and lots
Serial Numbers: Model: 2470-0100 (51 units) DG01130134 DG02130152 DG03130216 DG03130255 DG04130263 DG04130279 DG04130289 DG04130328 DG05129261 DG06106456 DG06129310 DG08129556 DG10129701 DG10129780 DG11129850 DG11129872 DG12118702 DG12120031 DG12129891 SGWZ02140093 SGWZ02140094 SGWZ03140098 SGWZ03140099 SGWZ03140100 SGWZ05140104 SGWZ06150243 SGWZ07150244 SGWZ09150248 SGWZ10150252 SGWZ11150255 SGWZ12130001 SGWZ16140132 SGWZ17140137 SGWZ19140144 SGWZ20140148 SGWZ21130009 SGWZ21140151 SGWZ24130019 SGWZ27130021 SGWZ27140166 SGWZ29140171 SGWZ31140175 SGWZ34130035 SGWZ36130038 SGWZ37140196 SGWZ45130061 SGWZ45130067 SGWZ48140219 SGWZ49140222 SGWZ50130086 SGWZ52130091  Model: 3470-0100 (3 units)  DG11129817, SGWZ21130010,SGWZ27140163

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2127-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2124-2015Class IITerminatedVoluntary: Firm initiated
Z-2125-2015Class IITerminatedVoluntary: Firm initiated
Z-2126-2015Class IITerminatedVoluntary: Firm initiated
Z-2127-2015Class IITerminatedVoluntary: Firm initiated