Attune Fb Cr Articulation Surface Size 3-8
DePuy Orthopaedics, Inc. began a recall of ATTUNE FB CR ARTICULATION SURFACE SIZE 3-8 INTENDED USE: The Tibial Articulation Surface Trial snaps together with the Shim component to function as the Insert... on . FDA classified it as Class II and gives the reason as "Potential for the Balseal, a small wire spring coil located on the post feature of the ATTUNE Knee Tibial Articulation Surface Instruments used in trialing to become damaged and disassociate (come off). If the Balseal...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-2138-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Depuy Orthopaedics Inc.
- Product
- ATTUNE FB CR ARTICULATION SURFACE SIZE 3-8 INTENDED USE: The Tibial Articulation Surface Trial snaps together with the Shim component to function as the Insert Trial during a total knee replacement. A Balseal is attached to each of the two post features on the Articulation Surface to provide a connection force between the Tibial Articulation Surface and Shim to ensure secure engagement between the components.
- Product code
- MBH Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
- Reason for recall
- Potential for the Balseal, a small wire spring coil located on the post feature of the ATTUNE Knee Tibial Articulation Surface Instruments used in trialing to become damaged and disassociate (come off). If the Balseal is separated from the post, it has the potential to enter the surgical site and be left in the patient if the surgeon is unaware of the disassociation.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- URGENT INFORMATION: MEDICAL DEVICE CORRECTION was issued for all lots of the affected devices. The device correction is to inform US Distributors and Medical Professionals about the issue, how to prevent the issue, and any actions to take. US Distributors will provide Hospitals/User Facilities with the Medical Professional Notice and Acknowledgment Cards. US Distributors will also work with the sales consultants to ensure all consultants complete sales training regarding this issue.
- Quantity in commerce
- 42645 units
- Distribution
- Worldwide Distribution - US including AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, and WY and Internationally to CANADA , AUSTRALIA, AUSTRIA, BELGIUM, ENGLAND/ UK, FRANCE, GERMANY, HONG KONG, INDIA, INDONESIA, IRELAND, ISRAEL, ITALY, JAPAN, JAPAN, MALAYSIA, NETHERLANDS, NEW ZEALAND, SINGAPORE, SLOVAKIA, SOUTH AFRICA, SOUTH KOREA, SPAIN & IBERIA, SWEDEN, SWITZERLAND, THAILAND, UAE, CHILE, COLOMBIA, MEXICO, PERU, and PUERTO RICO.
- Product codes and lots
- Product Codes: 254500523, 254500524, 254500525, 254500526, 254500527, and 254500528. GTIN: 10603295132639, 10603295132646, 10603295132653, 10603295132660, 10603295132677, and 10603295132684.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2137-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2138-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2139-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2140-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2141-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2142-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2143-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2144-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2145-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2146-2015 | Class II | Terminated | Voluntary: Firm initiated |