Hamilton Medical Infant Flow Sensor, single use, (1.6m), Part number 260177. The infant flow sensor is an...

Hamilton Medical AG / initiated 2015-06-01 / Terminated / root cause: design

Hamilton Medical, Inc. began a recall of Hamilton Medical Infant Flow Sensor, single use, (1.6m), Part number 260177. The infant flow sensor is an accessory for the Hamilton Medical Ventilators... on . FDA classified it as Class II and gives the reason as "An issue has been discovered with the Hamilton Medical Infant Flow Sensor, single use. When a ventilation mode with adaptive volume control (APVcmv/CMV+) is used, the ventilator may adjust the ventilation on the...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-1963-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Hamilton Medical AG
Product
Hamilton Medical Infant Flow Sensor, single use, (1.6m), Part number 260177. The infant flow sensor is an accessory for the Hamilton Medical Ventilators. Product Usage: The infant flow sensor is a device to measure patient air flow and pressures within the Hamilton Medical Ventilators.
Product code
BZO Set, Tubing And Support, Ventilator (W Harness)
Reason for recall
An issue has been discovered with the Hamilton Medical Infant Flow Sensor, single use. When a ventilation mode with adaptive volume control (APVcmv/CMV+) is used, the ventilator may adjust the ventilation on the inaccurate flow measurement and decrease the amount of ventilation delivered.
Root cause tag
design
FDA root cause
Device Design
Action
Hamilton Medical Inc sent a Medical Device Safety Notices letter dated May 8, 2015 by traceable method to affected customers. The letter identified the affected product, problem and actions to be taken. For questions contact Technical Support Manager at 800-426-6331, Ext 215.
Quantity in commerce
154 total - all part numbers
Distribution
US Nationwide Distribution.
Product codes and lots
PN 260177, all lot codes.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1963-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1963-2015Class IITerminatedVoluntary: Firm initiated
Z-1964-2015Class IITerminatedVoluntary: Firm initiated
Z-1965-2015Class IITerminatedVoluntary: Firm initiated