Z-1980-2015Class II

GE Healthcare Innova IGS 520. Angiographic X-ray systems used in generating fluoroscopic and rotational...

GE Healthcare / initiated 2015-05-29 / Terminated / root cause: manufacturing process

GE Healthcare began a recall of GE Healthcare Innova IGS 520. Angiographic X-ray systems used in generating fluoroscopic and rotational images of human anatomy for diagnostic, interventional... on . FDA classified it as Class II and gives the reason as "GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery)". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-1980-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
GE Healthcare
Product
GE Healthcare Innova IGS 520. Angiographic X-ray systems used in generating fluoroscopic and rotational images of human anatomy for diagnostic, interventional and image-guided surgical procedures.
Product code
IZI System, X-Ray, Angiographic
Reason for recall
GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery).
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
The firm, GE Healthcare, sent an "Urgent Medical Device Correction" letter on 5/29/2015- GEHC Ref#12231- dated May 29, 2015 to their Consignees. The letter described the Safety Issue, Safety Instructions, Affected Product Details, Product Correction, and contact Information. The customers were instructed that you may continue to use the system and avoid rapid direction changes with the gantry motions and prevent potential collisions with other equipment. If the failure occurs during interventional examination, please ensure that you have established procedures for handling patients in case of the loss of gantry motion as stated in your product labeling. GE Healthcare will correct all affected products at no cost to you. A GE Healthcare representative will contact you to arrange for this correction. If you have any questions or concerns regarding this notification, please contact GE Healthcare Service at 1-800-437-1171 or your local Service Representative.
Quantity in commerce
10
Distribution
Worldwide Distribution: US (nationwide) including states of: CA, DE, FL, GA, IL, IN, KS, MS, NV, OH, OK, OR, PA, TN, TX, VA, WA and WI; and countries of: ARGENTINA, BELGIUM, BRAZIL, CANADA, CHILE, CHINA, FRANCE, GERMANY, HONG KONG, HUNGARY, INDIA, INDONESIA, ITALY, JAPAN, RUSSIA, UNITED KINGDOM, and VIETNAM.
Product codes and lots
Serial Number System ID 0000013C2S0065 302421IGS520 15C2R0058 LVIGS2 15C2R0065 AM1396F508 15C2R0082 206598UIGS 15C2R0092 AM135FE37 0000015C2R0062 HU1117VA01 0000015C2R0057 083016848125215 0000015C2R0069 5512XR0026  0000015C2R0060 00632VAS01 0000015C2R0080 00391VAS02

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1980-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1973-2015Class IITerminatedVoluntary: Firm initiated
Z-1974-2015Class IITerminatedVoluntary: Firm initiated
Z-1975-2015Class IITerminatedVoluntary: Firm initiated
Z-1976-2015Class IITerminatedVoluntary: Firm initiated
Z-1977-2015Class IITerminatedVoluntary: Firm initiated
Z-1978-2015Class IITerminatedVoluntary: Firm initiated
Z-1979-2015Class IITerminatedVoluntary: Firm initiated
Z-1980-2015Class IITerminatedVoluntary: Firm initiated
Z-1981-2015Class IITerminatedVoluntary: Firm initiated
Z-1982-2015Class IITerminatedVoluntary: Firm initiated
Z-1983-2015Class IITerminatedVoluntary: Firm initiated
Z-1984-2015Class IITerminatedVoluntary: Firm initiated
Z-1985-2015Class IITerminatedVoluntary: Firm initiated