IMPAX Agility. IMPAX Agility when deployed as a departmental Picture Archiving and communications system...
AGFA Healthcare Corp. began a recall of IMPAX Agility. IMPAX Agility when deployed as a departmental Picture Archiving and communications system (PACS) provides an interface for the acquisition... on . FDA classified it as Class II and gives the reason as "Firm received a complaint that the hospital had sent two accession numbers over the same morning and on the Agility side the patient name was incorrect". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-2061-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- AGFA Healthcare Corp.
- Product
- IMPAX Agility. IMPAX Agility when deployed as a departmental Picture Archiving and communications system (PACS) provides an interface for the acquisition, display, digital processing, annotation, review, printing, storage and distribution of multimodality medical images, reports and demographic information for diagnostic purposes within the system and across computer networks.
- Product code
- LLZ System, Image Processing, Radiological
- Reason for recall
- Firm received a complaint that the hospital had sent two accession numbers over the same morning and on the Agility side the patient name was incorrect.
- FDA root cause
- Other
- Action
- PRB0046372 was created to address the corrective actions related to this issue. On 6/26/2015, an email communication, as an effectiveness check was sent to the two customers. Acknowledgment, via email, that the communication was received was requested from the consignees.
- Quantity in commerce
- 2
- Distribution
- Distributed in the state of MO.
- Product codes and lots
- N/A
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2061-2015 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY