Z-2198-2015Class II

GEMINI TF Base CT/PET System. The Philips GEMINI PET/CT Imaging Systems are a family of integrated diagnostic...

Philips North America LLC / initiated 2015-07-01 / Terminated / root cause: software

Philips Medical Systems (Cleveland) Inc began a recall of GEMINI TF Base CT/PET System. The Philips GEMINI PET/CT Imaging Systems are a family of integrated diagnostic X-ray Computed Tomography (CT) and Positron... on . FDA classified it as Class II and gives the reason as "Philips has identified four (4) software defects in the Tumor LOC software application that may potentially result in irradiation of healthy tissue or non-irradiation of diseased tissue". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-2198-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Philips North America LLC
Product
GEMINI TF Base CT/PET System. The Philips GEMINI PET/CT Imaging Systems are a family of integrated diagnostic X-ray Computed Tomography (CT) and Positron Emission Tomography (PET) systems suitable for a wide range of diagnostic applications.
Product code
KPS System, Tomography, Computed, Emission
Reason for recall
Philips has identified four (4) software defects in the Tumor LOC software application that may potentially result in irradiation of healthy tissue or non-irradiation of diseased tissue.
Root cause tag
software
FDA root cause
Software design
Action
On 7/6/2015 the firm sent Field Safety Notices to their customers.
Quantity in commerce
2 Units
Distribution
Worldwide Distribution - US Nationwide, Australia, Belgium, Brazil, Canada, China, Denmark, France, Germany, Israel, Italy, Japan, Lebanon, Netherlands, Portugal, Saudi Arabia, South Africa, Switzerland, Thailand, Venezuela & Vietnam.
Product codes and lots
Model #882473 GEMINI TF Base (453567441711); Serial Number: 7111 & 7150.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2198-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2193-2015Class IITerminatedVoluntary: Firm initiated
Z-2194-2015Class IITerminatedVoluntary: Firm initiated
Z-2195-2015Class IITerminatedVoluntary: Firm initiated
Z-2196-2015Class IITerminatedVoluntary: Firm initiated
Z-2197-2015Class IITerminatedVoluntary: Firm initiated
Z-2198-2015Class IITerminatedVoluntary: Firm initiated
Z-2199-2015Class IITerminatedVoluntary: Firm initiated