Z-2787-2015Class II

Terumo Custom Cardiovascular Procedure Kit X-Coated Adult Pak P/N: 73124 Terumo Cardiovascular Procedure Kits...

Terumo Cardiovascular Systems Corporation / initiated 2015-08-24 / Terminated / root cause: manufacturing process

Terumo Cardiovascular Systems Corp began a recall of Terumo Custom Cardiovascular Procedure Kit X-Coated Adult Pak P/N: 73124 Terumo Cardiovascular Procedure Kits are manufactured and customized to the design and... on . FDA classified it as Class II and gives the reason as "Custom Cardiovascular Procedure Kits contain recalled component Medivators HPH700 High Performance Hemoconcentrators". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2787-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Terumo Cardiovascular Systems Corporation
Product
Terumo Custom Cardiovascular Procedure Kit X-Coated Adult Pak P/N: 73124 Terumo Cardiovascular Procedure Kits are manufactured and customized to the design and specifications of the purchaser and/or the purchaser's principal technical representative for the application intended by the end user. The kits are comprised of a variety of legally marketed medical devices [including Medivators HPH700 High Performance Hemoconcentrators]. The Hemocor HPH700 Hemoconcentrator is intended for use as an ultrafiltration system to remove excess fluid during and/or following cardiopulmonary bypass procedures where acute hemodilution has been employed
Product code
N/A
Reason for recall
Custom Cardiovascular Procedure Kits contain recalled component Medivators HPH700 High Performance Hemoconcentrators
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
Terumo CVS issued an Urgent Medical Device Recall Notice dated August 24, 2015, to consignees via express mail. The letter advised users to immediately quarantine affected Cardiovascular Procedure Kits and stop using the Hemocor HPH700 Hemoconcentrator within the kit. Replacement sterile, stand-alone Hemocor HPH700 Hemoconcentrators will accompany the letter so that users may replace the affected emoconcentrators at the point of use. The option of replacing the hemoconcentrator at the point of use is offered to facilitate imminently scheduled cardiopulmonary bypass procedures. Users are requested to return the unused hemoconcentrators to Terumo CVS. Alternatively, users may return the entire Cardiovascular Procedure Kit to Terumo CVS for replacement. Customers with questions were instructed to call 763-553-3348.
Quantity in commerce
32 kits
Distribution
Nationwide Distribution including CA, CT , FL , WI.
Product codes and lots
Lot Numbers: TD02,TD02A, TD23, TD23A

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2787-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2786-2015Class IITerminatedVoluntary: Firm initiated
Z-2787-2015Class IITerminatedVoluntary: Firm initiated
Z-2788-2015Class IITerminatedVoluntary: Firm initiated
Z-2789-2015Class IITerminatedVoluntary: Firm initiated
Z-2790-2015Class IITerminatedVoluntary: Firm initiated
Z-2791-2015Class IITerminatedVoluntary: Firm initiated
Z-2792-2015Class IITerminatedVoluntary: Firm initiated