SOMATOM Definition Edge; intended to produce cross-sectional images of the body by computer reconstruction of...
Siemens Medical Solutions USA, Inc began a recall of SOMATOM Definition Edge; intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same... on . FDA classified it as Class II and gives the reason as "software bug issues for SW-Version VA48A_SP0. The following safety issues were resolved: 1) Correction to improve visual warning and error indication son the gantry display. 2) Correction to improve acquisition data in...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-0019-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Siemens Medical Solutions USA, Inc.
- Product
- SOMATOM Definition Edge; intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial plane taken at different angles or spiral planes taken at different angles.
- Product code
- JAK System, X-Ray, Tomography, Computed
- Reason for recall
- software bug issues for SW-Version VA48A_SP0. The following safety issues were resolved: 1) Correction to improve visual warning and error indication son the gantry display. 2) Correction to improve acquisition data in order to optimize image quality. 3) Correction to improve robustness and general system behavior in some exception handling procedures. 4) Correction to improve auto post processin
- Root cause tag
- software
- FDA root cause
- Software design
- Action
- A customer advisory notice, dated 8/14/15, was sent to direct accounts advising them of the issue to observe the safety notice and comply with the corresponding measure until the update has been fully completed.
- Quantity in commerce
- 113 total
- Distribution
- Nationwide Distribution.
- Product codes and lots
- Model#' 10590000 with Serial numbers 83277 83281 83021 83004 83014 83276 83279
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0019-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0020-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0021-2016 | Class II | Terminated | Voluntary: Firm initiated |