SOMATOM Definition AS, intended to produce cross-sectional images of the body by computer reconstruction of...
Siemens Medical Solutions USA, Inc began a recall of SOMATOM Definition AS, intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial... on . FDA classified it as Class II and gives the reason as "software bug issues for SW-Version VA48A_SP0. The following safety issues were resolved: 1) Correction to improve visual warning and error indication son the gantry display. 2) Correction to improve acquisition data in...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-0021-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Siemens Medical Solutions USA, Inc.
- Product
- SOMATOM Definition AS, intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial plane taken at different angles or spiral planes taken at different angles.
- Product code
- JAK System, X-Ray, Tomography, Computed
- Reason for recall
- software bug issues for SW-Version VA48A_SP0. The following safety issues were resolved: 1) Correction to improve visual warning and error indication son the gantry display. 2) Correction to improve acquisition data in order to optimize image quality. 3) Correction to improve robustness and general system behavior in some exception handling procedures. 4) Correction to improve auto post processin
- Root cause tag
- software
- FDA root cause
- Software design
- Action
- A customer advisory notice, dated 8/14/15, was sent to direct accounts advising them of the issue to observe the safety notice and comply with the corresponding measure until the update has been fully completed.
- Quantity in commerce
- 113 total
- Distribution
- Nationwide Distribution.
- Product codes and lots
- Model#' 8098027 with Serial numbers 66441 95601 95610 65831 65868 95596 95600 95604 65968 66506 95043 95582 65764 95602 66146 65578 95584 66476 95578 66467 95609 66503 66475 66455 65597 65233 95599 64942 65446 66396 95474 66304 66423 66473 66473 95438 95581 66232 66173 66404 95491 66514 66321 65583 65586 66457 66490 66253 95579 66579 95593 95575 95592 66001 66407 95580 65693 66112 66470 95591 95559 66434 66230 95608 95510 66303
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0019-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0020-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0021-2016 | Class II | Terminated | Voluntary: Firm initiated |