Z-0155-2016Class II

Smith & Nephew MOSAICPLASTY DP- Disposable Harvesting System 3.5 mm, Sterile Part Number: 7209234

Smith & Nephew, Inc. / initiated 2015-09-10 / Terminated / root cause: packaging

Smith & Nephew, Inc., Endoscopy Div. began a recall of Smith & Nephew MOSAICPLASTY DP- Disposable Harvesting System 3.5 mm, Sterile Part Number: 7209234 Intended Use: For arthroscopic (knee and ankle) and open... on . FDA classified it as Class II and gives the reason as "Sterility of device is compromised due to breach in the packaging". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.

Recall record

Recall number
Z-0155-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Smith & Nephew, Inc.
Product
Smith & Nephew MOSAICPLASTY DP- Disposable Harvesting System 3.5 mm, Sterile Part Number: 7209234 Intended Use: For arthroscopic (knee and ankle) and open osteochondral grafting fix for osteochondral (cartilage) defects.
Product code
HWE Instrument, Surgical, Orthopedic, Ac-Powered Motor And Accessory/Attachment
Reason for recall
Sterility of device is compromised due to breach in the packaging
Root cause tag
packaging
FDA root cause
Package design/selection
Action
Smith & Nephew issued Recall Notification Letter dated September 10, 2015 via overnight Federal Express. Customers were requested to inspect inventory and locate any unused devices from the above listed product and batch numbers, and quarantine them immediately. Complete the Inventory Return Certification Form on the following page, indicating the lot numbers and quantities that need to be returned and include your phone and fax number in the spaces provided. If you do not have product to return, please place an x in the column No product to return. Send the completed form to the Smith & Nephew's Field Action Department via email at FieldActions@smithnephew. com or fax +1-901-566-7975 to obtain a return authorization (RA) number. Return any affected product to the address listed on the Inventory Return Certification Form. Please indicate the RA number on your return shipment.
Quantity in commerce
603 units
Distribution
Worldwide Distribution - US Nationwide, Canada, Austria, Australia, Belgium, China, Spain, Finland, France, Great Britain, Greece, Germany, Hungary, India, Italy, Japan, Korea, Lithuania, Latvia, Netherlands, Poland, Portugal, Sweden, Thailand, Turkey, Ukraine and Venezuela
Product codes and lots
Lot Numbers: 50045108 50216535 50337080 50381998 50444238 50069259 50225422 50337457 50387855 50451052 50078520 50237917 50340700 50401825 50451745 50105330 50239234 50340703 50408124 50452070 50108397 50244752 50349035 50413603 50455381 50113533 50247214 50350233 50416389 50456956 50118206 50250359 50354625 50425909 50128288 50258565 50356930 50427082 50200340 50271899 50372415 50436696 50207484 50333910 50378455 50437933

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0155-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0155-2016Class IITerminatedVoluntary: Firm initiated
Z-0156-2016Class IITerminatedVoluntary: Firm initiated
Z-0157-2016Class IITerminatedVoluntary: Firm initiated
Z-0158-2016Class IITerminatedVoluntary: Firm initiated