Z-0260-2016Class II

GE Healthcare, SIGNA PET/MR 3.0T

GE Healthcare / initiated 2015-08-31 / Terminated / root cause: software

GE Healthcare began a recall of GE Healthcare, SIGNA PET/MR 3.0T. Product Usage: The SIGNA PET/MR system combines magnetic resonance diagnostic devices (MRDD) and Positron Emission Tomography... on . FDA classified it as Class II and gives the reason as "When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-0260-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
GE Healthcare
Product
GE Healthcare, SIGNA PET/MR 3.0T. Product Usage: The SIGNA PET/MR system combines magnetic resonance diagnostic devices (MRDD) and Positron Emission Tomography (PET) scanners that provide registration and fusion of high-resolution physiologic and anatomic information, acquired simultaneously and isocentrically.
Product code
OUO Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
Reason for recall
When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could exceed IEC60601-2-33 limit of 3.2 W/kg for some scans.
Root cause tag
software
FDA root cause
Software design
Action
GE Healthcare sent an Urgent Medical Device Correction letter dated August 31, 2015. The letter was addressed to Hospital Administrators/Risk Managers, Radiology Department Managers, & Radiologists. The letter described the Safety Issue, Safety Instructions, Affected Product Details, Product Correction and Contact Information. For questions contact GE Healthcare Service at 1-800-437-1171 or your local Service Representative.
Quantity in commerce
17
Distribution
Worldwide Distribution - US: Nationwide including DC, PR and GU and the countries of ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, AZERBAIJAN, BAHRAIN, BELARUS, BELGIUM, BERMUDA, BOSNIA HERZEGOVINA, BRAZIL, BULGARIA, CANADA, CHINA, CZECH REPUBLIC, DENMARK, EGYPT, ESTONIA, ETHIOPIA, FINLAND, FRANCE, GERMANY, GREECE, HONG Kong, HUNGARY, INDIA, INDONESIA, IRAN, IRELAND, ISRAEL, ITALY, JAMAICA, JAPAN, KAZAKHSTAN, REPUBLIC OF KOREA, KUWAIT, LEBANON, LUXEMBOURG, MALAYSIA, MEXICO, NETHERLANDS, NEW ZEALAND, NORWAY, PERU, POLAND, PORTUGAL, QATAR, ROMANIA, RUSSIA, SAUDI ARABIA, SERBIA, SINGAPORE, SLOVENIA, SOUTH AFRICA, SPAIN, SWEDEN, SWITZERLAND, SYRIA, TAIWAN, THAILAND, TURKEY, UNITED ARAB EMIRATES, UNITED KINGDOM, URUGUAY, and VENEZUELA.
Product codes and lots
00000000UA0064 415723SHMRW 00000000UA0217 415CBMRP N/A 608262PETMR1  MAYOPETMR01  UABPETMR  SID TBD  SID TBD  262574PETMR1 310974MR1 MRUA0459 309452MR1 082427HWBAY1  M40345211 N/A SID TBD  SID TBD  SID TBD 00001309FMM076 C001MR01 00000309668MR2 AC001MR02 00000307417MR6 120810MR03

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0260-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0254-2016Class IITerminatedVoluntary: Firm initiated
Z-0255-2016Class IITerminatedVoluntary: Firm initiated
Z-0256-2016Class IITerminatedVoluntary: Firm initiated
Z-0257-2016Class IITerminatedVoluntary: Firm initiated
Z-0258-2016Class IITerminatedVoluntary: Firm initiated
Z-0259-2016Class IITerminatedVoluntary: Firm initiated
Z-0260-2016Class IITerminatedVoluntary: Firm initiated