RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Floppy. REF H802223301...
Boston Scientific Corporation began a recall of RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Floppy. REF H802223301 (5-pack outer package), REF H802223300 (single unit)... on . FDA classified it as Class I and gives the reason as "Boston Scientific is recalling its recently released RotaWire Elite Guidewire and wireClip Torquer Guidewire Manipulation device that is used in conjunction with the Rotablator Rotational Atherectomy System because of...". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-0211-2016
- Classification
- Class I
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Boston Scientific Corporation
- Product
- RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Floppy. REF H802223301 (5-pack outer package), REF H802223300 (single unit). The Rotablator rotational atherectomy system consists of a diamond tipped burr capable of high speed rotation designed for plaque modification and debulking in vascular interventions. This system is designed to travel over a specialized 0.009 guidewire to guide the path of burr travel to deliver therapy where intended. The guidewires are intended for use with the Rotablator Rotational Atherectomy System.
- Product code
- MCX Catheter, Coronary, Atherectomy
- Reason for recall
- Boston Scientific is recalling its recently released RotaWire Elite Guidewire and wireClip Torquer Guidewire Manipulation device that is used in conjunction with the Rotablator Rotational Atherectomy System because of complaints of wire fracture.
- FDA root cause
- Component change control
- Action
- The firm, Boston Scientific, sent an "Urgent Medical Device Recall Removal - Immediate Action Required" letter dated 10/9/2015. Letters were sent via overnight delivery (FedEx or other equivalent service). The letter stated the issue, identified affected devices, stated that further distribution or use of the devices should cease immediately, and affected product should be returned to Boston Scientific in accordance with the enclosed recall instructions. Complete and return the Recall Instructions via email: [email protected] or Fax to: Field Action Center 1-866-213-1806. Healthcare professionals and consumer may report serious adverse events (side effects ) or product quality problems with the use of this product to Boston Scientific by calling 1-800-811-3211. If you have any questions, please contact Boston Scientific Quality Systems at 763-494-1133, email: [email protected] or your local sales representative can answer any questions that you may have regarding this recall removal.
- Quantity in commerce
- 955 single units (191 5-packs)
- Distribution
- Worldwide Distribution: US Distribution in the states of AZ, CA, DE, FL, GA, IL, LA, MD, MI, MN, NE, NY, PA, SC, TX, WA, and WI, and the countries of Belgium, Germany, Great Britain, Italy, Japan, and South Africa.
- Product codes and lots
- Lots: 18201519, 18212726, 18256610, 18261218, 18271412, 18282032, 18362094, 18378161, 18379210, 18384443
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0211-2016 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0212-2016 | Class I | Terminated | Voluntary: Firm initiated |