Z-0268-2016Class II

Medtronic Perfusion Tubing Packs, Models TL7M64R3, TL7P17R1 & HY2W85R9, Sterilized using Ethylene Oxide. The...

Medtronic Perfusion Systems / initiated 2015-10-28 / Terminated / root cause: packaging

Medtronic Perfusion Systems began a recall of Medtronic Perfusion Tubing Packs, Models TL7M64R3, TL7P17R1 & HY2W85R9, Sterilized using Ethylene Oxide. The Tubing Pack design and components are specified by... on . FDA classified it as Class II and gives the reason as "This recall is being initiated due to a potential breach of the Tubing Pack Header Bags manufactured in these select lots. The seal in question is between the Tyvek and the Poly side of the header bag". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.

Recall record

Recall number
Z-0268-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic Perfusion Systems
Product
Medtronic Perfusion Tubing Packs, Models TL7M64R3, TL7P17R1 & HY2W85R9, Sterilized using Ethylene Oxide. The Tubing Pack design and components are specified by the user, they are packaged with consideration of setup efficiency and respect for the environment, and they are intended for use in the extracorporeal circuit during cardiopulmonary bypass procedures. Medtronic Tubing Packs can contain components with Carmeda BioActive Surface, Trillium BioSurface, Balance BioSurface or no coating. Sterile barrier for these packs is provided either by a Tyvek lid seal on the tray or by a header bag.
Product code
DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
Reason for recall
This recall is being initiated due to a potential breach of the Tubing Pack Header Bags manufactured in these select lots. The seal in question is between the Tyvek and the Poly side of the header bag.
Root cause tag
packaging
FDA root cause
Packaging process control
Action
Medtronic sent an Urgent Medical Device Recall letter dated October 2015 to all affected consignees. The letter described the problem and the product involved in the recall. Consignees were advised to quarantine and return all affected product and to complete and return the Customer Confirmation certificate. For questions contact your Medtronic representative or contact Medtronic's national Answering service at 800-633-8766.
Quantity in commerce
496
Distribution
Nationwide Distribution including US: AL, IL, IN, and WI.
Product codes and lots
Model Lot Numbers Lot Number HY2W85R9 209704344,209704345,209704346,  209704347,210010558    TL7M64R3 209789393 TL7P17R1 209789333

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0268-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0268-2016Class IITerminatedVoluntary: Firm initiated