DGDE, DirectGuide Drill Extender. Instrument for use with dental implants. A manufactured device that adds a...
Implant Direct Sybron Manufacturing, LLC began a recall of DGDE, DirectGuide Drill Extender. Instrument for use with dental implants. A manufactured device that adds a 6mm extension for a 25mm and 28mm tissue height... on . FDA classified it as Class II and gives the reason as "Implant Direct Sybron Manufacturing, LLC is recalling 26 lots of DGDE DirectGuide Drill Extender because of a possible dropping of the drill". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0396-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Implant Direct Sybron Manufacturing LLC
- Product
- DGDE, DirectGuide Drill Extender. Instrument for use with dental implants. A manufactured device that adds a 6mm extension for a 25mm and 28mm tissue height capability suitable for individual patient needs. The thru hole in the DGDE allows existing surgical drills to be inserted and locked in place.
- Product code
- NHA Abutment, Implant, Dental, Endosseous
- Reason for recall
- Implant Direct Sybron Manufacturing, LLC is recalling 26 lots of DGDE DirectGuide Drill Extender because of a possible dropping of the drill.
- Root cause tag
- manufacturing process
- FDA root cause
- Unknown/Undetermined by firm
- Action
- On 10/28/15 customer notification letters were sent. Within the letter the firm states that if customers have any of the affected product listed to contact the firm's Customer Care at 1-888-649-6425. A return label is provided with notification. The firm states that if customers are an authorized Implant Direct Sybron Manufacturing distributor they request that they identify their customers that have been shipped the affected product, and contact them within 48 hours of receiving notification in order to obtain the product. The letter states if any customers or patients have experienced any issues as a result of the affected products to report the incident to the FDA through he MEDWATCH reporting system.
- Quantity in commerce
- 478
- Distribution
- Worldwide Distribution- US (nationwide) including the states of CA, FL, TX, MO, MI, MA, NV, OR, PA, AZ, IL, VA, OH, GA, and SC, and the country of Canada, Poland, Serbia, Italy, Germany, Cairo, Jordan, El Salvador, Kuwait, Costa Rica, Switzerland, Colombia, United Kingdom, Austria, Netherlands, Chile, and Egypt.
- Product codes and lots
- Parts Numbers: DGDE, SPCST, IBST, BST, CST, ICST, IBST, RBST, RCST Lot Number: 61928, 64895, 64898, 64896, 65406, 65405, 65407, 65408, 65410, 65409, 65357, 67055, 67475, 67345, 37475, 67476, 67474, 67478, 67477, 67479, 67527, 68254, 68266, 68253, 68265, 68262
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0396-2016 | Class II | Terminated | Voluntary: Firm initiated |