Z-0795-2016Class II
PharmaCaribe PulmoSal 7% Sodium chloride, Inhalation Solution, 7% Sterile, Preservative -free, Non-pyrogenic...
Pharmacaribe LLC / initiated 2015-12-29 / Terminated / root cause: labeling and UDI
Pharmacaribe llc began a recall of PharmaCaribe PulmoSal 7% Sodium chloride, Inhalation Solution, 7% Sterile, Preservative -free, Non-pyrogenic, pH 7.4 For Inhalation Only Rx Product Usage: The... on . FDA classified it as Class II and gives the reason as "Vials were labeled as USP 7% Hypertonic saline instead of PulmoSal 7% (pH+)". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-0795-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Pharmacaribe LLC
- Product
- PharmaCaribe PulmoSal 7% Sodium chloride, Inhalation Solution, 7% Sterile, Preservative -free, Non-pyrogenic, pH 7.4 For Inhalation Only Rx Product Usage: The contents of these vials are used in conjunction with a nebulizer for the induction of sputum production where sputum production is indicated.
- Product code
- CAF Nebulizer (Direct Patient Interface)
- Reason for recall
- Vials were labeled as USP 7% Hypertonic saline instead of PulmoSal 7% (pH+)
- Root cause tag
- labeling and UDI
- FDA root cause
- Error in labeling
- Action
- PharmaCaribe, together with its Contract Manufacturing firm Asept Pak, Inc., have initiated or completed the following actions to issued an Urgent Notice: Field Notification to Medical Device letter dated January t7, 2016. The letter identified the affected product, problem and actions to be taken. The letter instructed customers to: Determine what is on hand and what has been distributed. Using the Return Notice provided, report this information as per the instructions on the notice. Please record units as either cases or as cartons (if the cases have been opened and are partial). This document is to be returned via mail or email as per the guidance provided. This will inform the Manufacturer of your inventory status and of your intentions regarding product replacement. Cases of this product may be returned for new cases of the same product (different lot) that have the correct embossing on the vials. Instructions for return are provided in the Field Notification Package Cover Letter. Alternatively, customers may choose to be issued a full refund for all returned product. For cases which have already been distributed to the retail/clinician level and/or are in use by patients, it is acceptable to continue to use the product, with the understanding (and proper communication to all parties) that the tabs on the vials are incorrectly labeled. Contact information: Lisa Early, QA Manager Asept Pak, Inc. Phone: 518-651-2026 Fax: 518-651-2046 E-mail: [email protected]
- Quantity in commerce
- 7,020 vials
- Distribution
- US Nationwide Distribution in the states of FL, LA, TX and VA
- Product codes and lots
- Lot # CIY Exp.Date August 2017 UPC Number: 030915339988 (on the box of 60 vials) UPC Number: 10030915339985 (on the shipping case of 12 boxes)
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0795-2016 | Class II | Terminated | Voluntary: Firm initiated |