Z-1181-2016Class II

Puritan Bennett 980 Ventilator System, PB980 Ventilator (980xxxxxxxx). Intended to provide continuous...

Medtronic, Inc. / initiated 2016-01-15 / Terminated

Covidien LP (formerly Nellcor Puritan Bennett Inc.) began a recall of Puritan Bennett 980 Ventilator System, PB980 Ventilator (980xxxxxxxx). Intended to provide continuous ventilation for pediatric and adult patients who require... on . FDA classified it as Class II and gives the reason as "Graphical user interface (GUI) unresponsive to touch and Loss of primary ventilation under certain circumstances. Covidien Respiratory and Monitoring Solutions, now a part of Medtronic, issued a field corrective action...". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-1181-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic, Inc.
Product
Puritan Bennett 980 Ventilator System, PB980 Ventilator (980xxxxxxxx). Intended to provide continuous ventilation for pediatric and adult patients who require either invasive ventilation or non-invasive ventilation.
Product code
CBK Ventilator, Continuous, Facility Use
Reason for recall
Graphical user interface (GUI) unresponsive to touch and Loss of primary ventilation under certain circumstances. Covidien Respiratory and Monitoring Solutions, now a part of Medtronic, issued a field corrective action notice for two issues on all models of Puritan Bennett 980 (PB980) ventilator.
FDA root cause
Under Investigation by firm
Action
Customers were notified via an Urgent Medical Device Safety Notification, dated February 8, 2016, on 1/14/16. The letter identified the affected device and the issues involved. Consignees are requested to forward the recall letter to anyone they may have transferred or assigned for use one of the potentially affected ventilators. Medtronic is investigating the root cause of these conditions and will provide a service update to resolve the issues as soon as corrections can be implemented. Customers are to complete the attached form and return it per the instructions to confirm receipt and understanding of the information. Questions or issues should be directed to the Technical Support Department at 800-255-6774.
Quantity in commerce
1,864 units
Distribution
Worldwide Distribution -- US, including but not limited to the territory of Puerto Rico; and Ireland, Jordan, Saudi Arabia, Bahrain, Australia, Japan, Israel, Turkey, Chile, South Africa, Costa Rica, United Arab Emirates, Qatar, Peru, Panama, Singapore, Kuwait, Lebanon, Brazil, Mexico, Colombia, Russia, Uruguay, Slovenia, Morocco, Argentina, Egypt, and Romania.
Product codes and lots
all versions of software.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1181-2016