510(K) CLEARANCES 67 ▼8RECALLS POSTED 26CLASS I 2PMA DECISIONS 40 ▼14WEEK ENDING / FDA DATA AS OF
Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0846-2016Class II

VERSYS 6 INCH BEADED FC 1 prosthesis, hip, semi-constrained, metal/polymer, porous uncemented "" Total hip...

Zimmer GmbH / initiated 2016-01-11 / Terminated / root cause: manufacturing process

Zimmer Biomet, Inc. began a recall of VERSYS 6 INCH BEADED FC 1 prosthesis, hip, semi-constrained, metal/polymer, porous uncemented "" Total hip replacement for the following: severe hip pain and... on . FDA classified it as Class II and gives the reason as "LDPE bag containing the implant adheres to the highly polished implant surface". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0846-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
VERSYS 6 INCH BEADED FC 1 prosthesis, hip, semi-constrained, metal/polymer, porous uncemented "" Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected extremity and acute femoral neck fractures. " Hemi-hip replacement for the following: fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected."
Product code
LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Reason for recall
LDPE bag containing the implant adheres to the highly polished implant surface.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
Zimmer Biomet sent an Urgent Medical Device Recall dated January 11, 2016, to all affected customers via courier with instructions for identifying and returning the affected product. The recall notification included a description of the reason for the recall, affected product, consignee responsibilities, and instructions for responding to the formal recall notification. Customers with questions or concerns were instructed to contact customer service at 1-800-348-2759 or contact their Zimmer Biomet Sales Representative. For questions regarding this recall call 800-447-5633.
Quantity in commerce
130
Distribution
Worldwide Distribution - US (nationwide) and Internationally to ARGENTINA AUSTRALIA AUSTRIA BARBADOS BELGIUM BERMUDA BOLIVIA BRAZIL CARIBBEAN CHILE CHINA COLOMBIA COST RICA DENMARK DOMINICAN REPUBLIC DORAL FL ECUADOR EL SALVADOR ENGLAND FRANCE GERMANY GUATEMALA HONDURAS HONG KONG INDIA ISRAEL ITALY JAMAICA JAPAN KOREA MALAYSIA MEXICO NEW ZEALAND NICARAGUA PANAMA PERU SINGAPORE SPAIN SWEDEN SWITZERLAND TAIWAN THAILAND VENEZUELA WEST INDIES Canary Islands Croatia Cyprus Czech Republic Canada
Product codes and lots
Item numbers: 00-7843-011-16 00-7843-012-16 00-7843-013-16 00-7843-014-16 00-7843-015-16 00-7843-016-16 Lot numbers: 61760685 61781980 61840199 61844725 61844726 61951281 61956725 61968111 61987956 62011958 62029062 62034145 62097248 62097288 62120672

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0846-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0830-2016Class IITerminatedVoluntary: Firm initiated
Z-0831-2016Class IITerminatedVoluntary: Firm initiated
Z-0832-2016Class IITerminatedVoluntary: Firm initiated
Z-0833-2016Class IITerminatedVoluntary: Firm initiated
Z-0834-2016Class IITerminatedVoluntary: Firm initiated
Z-0835-2016Class IITerminatedVoluntary: Firm initiated
Z-0836-2016Class IITerminatedVoluntary: Firm initiated
Z-0837-2016Class IITerminatedVoluntary: Firm initiated
Z-0838-2016Class IITerminatedVoluntary: Firm initiated
Z-0839-2016Class IITerminatedVoluntary: Firm initiated
Z-0840-2016Class IITerminatedVoluntary: Firm initiated
Z-0841-2016Class IITerminatedVoluntary: Firm initiated
Z-0842-2016Class IITerminatedVoluntary: Firm initiated
Z-0843-2016Class IITerminatedVoluntary: Firm initiated
Z-0844-2016Class IITerminatedVoluntary: Firm initiated
Z-0845-2016Class IITerminatedVoluntary: Firm initiated
Z-0846-2016Class IITerminatedVoluntary: Firm initiated
Z-0847-2016Class IITerminatedVoluntary: Firm initiated
Z-0848-2016Class IITerminatedVoluntary: Firm initiated
Z-0849-2016Class IITerminatedVoluntary: Firm initiated
Z-0850-2016Class IITerminatedVoluntary: Firm initiated