Z-2076-2016Class II

Ultrasound Bronchoscope Intended to provide optical visualization of, ultrasonic visualization of and...

PENTAX of America, Inc. / initiated 2016-04-06 / Terminated / root cause: design

Pentax Medical Company began a recall of Ultrasound Bronchoscope Intended to provide optical visualization of, ultrasonic visualization of and therapeutic access to, the Pulmonary Tract including but... on . FDA classified it as Class II and gives the reason as "Pentax has become aware that operational/cleaning accessories and therapeutic devices (e.g., clips, stents, balloons, etc.) can become lodged in an endoscope's instrument channel". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-2076-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
PENTAX of America, Inc.
Product
Ultrasound Bronchoscope Intended to provide optical visualization of, ultrasonic visualization of and therapeutic access to, the Pulmonary Tract including but not restricted to organs, tissues and subsystems: Nasal Passage, Pharynx, Larynx, Trachea, Bronchial Tree (including access beyond the stem), and underlying areas. The instrument is introduced orally when indications consistent with the requirement for procedure are observed in adult and pediatric patient populations
Product code
EOQ Bronchoscope (Flexible Or Rigid)
Reason for recall
Pentax has become aware that operational/cleaning accessories and therapeutic devices (e.g., clips, stents, balloons, etc.) can become lodged in an endoscope's instrument channel.
Root cause tag
design
FDA root cause
Device Design
Action
Pentax sent an Urgent Field Correction letter dated April 6, 2016 to all affected consignees. The letter identified the product, the problem, and the action to be taken by the consignee. Consignees were reminded to carefully check that all accessories are intact, that no parts have fallen off and become lodged within the endoscope's instrument/suction channel and to ensure that any therapeutic devices passed through the instrument channel are accounted for after use. If the instrument/suction channel does become blocked or clogged due to the accumulation of debris, an accessory that cannot be removed, or other cause, do NOT attempt to correct the blockage or continue to use the endoscope. Customers were instructed to contact their local PENTAX Medical Service facility to have the endoscope repaired. Customers with questions were instructed to call 800-431-5880, ext 2064.
Quantity in commerce
115 units
Distribution
Worldwide Distribution - US (Nation Wide) including Puerto Rico and Internationally to Denmark, Guam
Product codes and lots
Model #EB-1970UK

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2076-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2065-2016Class IITerminatedVoluntary: Firm initiated
Z-2066-2016Class IITerminatedVoluntary: Firm initiated
Z-2067-2016Class IITerminatedVoluntary: Firm initiated
Z-2068-2016Class IITerminatedVoluntary: Firm initiated
Z-2069-2016Class IITerminatedVoluntary: Firm initiated
Z-2070-2016Class IITerminatedVoluntary: Firm initiated
Z-2071-2016Class IITerminatedVoluntary: Firm initiated
Z-2072-2016Class IITerminatedVoluntary: Firm initiated
Z-2073-2016Class IITerminatedVoluntary: Firm initiated
Z-2074-2016Class IITerminatedVoluntary: Firm initiated
Z-2075-2016Class IITerminatedVoluntary: Firm initiated
Z-2076-2016Class IITerminatedVoluntary: Firm initiated
Z-2077-2016Class IITerminatedVoluntary: Firm initiated
Z-2078-2016Class IITerminatedVoluntary: Firm initiated
Z-2079-2016Class IITerminatedVoluntary: Firm initiated
Z-2080-2016Class IITerminatedVoluntary: Firm initiated