Philips Healthcare Ingenuity Core128 Computed Tomography X-Ray System
Philips Healthcare began a recall of Philips Healthcare Ingenuity Core128 Computed Tomography X-Ray System on . FDA classified it as Class II and gives the reason as "Software Defects resulting in: (1) sagittal result shortened for axial scans; (2) single series displayed on console viewer when Creating multi-planner reconstruction; (3) scan length changes with a change in field of...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-1718-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Philips North America LLC
- Product
- Philips Healthcare Ingenuity Core128 Computed Tomography X-Ray System
- Product code
- JAK System, X-Ray, Tomography, Computed
- Reason for recall
- Software Defects resulting in: (1) sagittal result shortened for axial scans; (2) single series displayed on console viewer when Creating multi-planner reconstruction; (3) scan length changes with a change in field of view; (4) DoseRight algorithm miscalculations leading to incorrect CTDI values; (5) scan length changes during subsequent axial results, (6) surview scan lengths near 135mm or 184mm
- Root cause tag
- software
- FDA root cause
- Radiation Control for Health and Safety Act
- Action
- Philips plans to initiate a field corrective action that will install a new software release to address the issue. Philips will modify the systems in the field to correct the defect at no cost to the customer. 1. You will contact customers and initiate a software update to correct the defect. 2. You will install the software and perform testing to ensure the software update was effective. 3. The customer notification letter which includes a statement that you will without charge, remedy the defect or bring the product into compliance. For further questions, please call (1-800) 722-9377, Option 5
- Quantity in commerce
- US - 423
- Distribution
- US Distribution - AZ, PA, FL, DC, W VA, NC, SC, AR, OK, OH, NY, NV, TX, PA, IN, CA, MN, MA, DC, MS, MD, OR, IL, CO, MO, VT, IA, AL, LA, GA and WA.
- Product codes and lots
- Software v. 4.13, 4.14 and 4.15.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1713-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1714-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1715-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1716-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1717-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1718-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1719-2016 | Class II | Terminated | Voluntary: Firm initiated |