Biograph mCT-S(64) 4R, MATERIAL NUMBER 10248672
Siemens Medical Solutions USA Inc. began a recall of Biograph mCT-S(64) 4R, MATERIAL NUMBER 10248672 Product Usage: The Siemens Biograph mCT systems are combined X-Ray Computed Tomography (CT) and Positron... on . FDA classified it as Class II and gives the reason as "The bracket that is used to lift the cover has bolts that were not welded in potentially causing the cover to fall down during service". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1998-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Siemens Medical Solutions USA, Inc.
- Product
- Biograph mCT-S(64) 4R, MATERIAL NUMBER 10248672 Product Usage: The Siemens Biograph mCT systems are combined X-Ray Computed Tomography (CT) and Positron Emission Tomography (PET) scanners that provide registration and fusion of high resolution physiologic and anatomic information.
- Product code
- KPS System, Tomography, Computed, Emission
- Reason for recall
- The bracket that is used to lift the cover has bolts that were not welded in potentially causing the cover to fall down during service.
- Root cause tag
- manufacturing process
- FDA root cause
- Process design
- Action
- Siemens sent a Customer Safety Advisory Letter to all affected customers. The letter identified the affected product, problem and actions to be taken. Siemens service organization will be contacting customers to schedule the update as per the attached Update Instruction and will be provided the replacement bracket to resolve the issue. For questions contact your Siemens representative.
- Quantity in commerce
- 2 units
- Distribution
- Worldwide Distribution - US Nationwide and the countries of China and Malaysia.
- Product codes and lots
- Serial Numbers: 31125,31126
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1997-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1998-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1999-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2000-2016 | Class II | Terminated | Voluntary: Firm initiated |