Z-2846-2016Class II

Broselow/Hinkle, PEDIATRIC EMERGENCY SYSTEM, PINK/RED Oxygen Delivery Module 2/PACK, Product Code 7700RAW2

Medtronic, Inc. / initiated 2016-06-29 / Terminated / root cause: labeling and UDI

Carefusion 2200 Inc began a recall of Broselow/Hinkle, PEDIATRIC EMERGENCY SYSTEM, PINK/RED Oxygen Delivery Module 2/PACK, Product Code 7700RAW2 on . FDA classified it as Class II and gives the reason as "The Oral Airway pouch within the PINK/RED Oxygen Delivery Module, 7700RAW, was incorrectly packaged with the 8 cm Berman Oral Airway. The pouch contained within the module is correctly labeled as 5 cm but actually...". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-2846-2016
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic, Inc.
Product
Broselow/Hinkle, PEDIATRIC EMERGENCY SYSTEM, PINK/RED Oxygen Delivery Module 2/PACK, Product Code 7700RAW2
Product code
CAE Airway, Oropharyngeal, Anesthesiology
Reason for recall
The Oral Airway pouch within the PINK/RED Oxygen Delivery Module, 7700RAW, was incorrectly packaged with the 8 cm Berman Oral Airway. The pouch contained within the module is correctly labeled as 5 cm but actually contains an 8 cm Berman Oral Airway component. Therefore, the component within the pouch is incorrect. The PINK/RED Oxygen Delivery Module, 7700RAW, is intended to be used within the PINK/RED Pouch of the BROSELOW pediatric safety system. Three (3) lots (lot# 914873, lot# 914876 and lot #914878) of the PINK/RED Oxygen Delivery Module, 7700RAW, are affected by this voluntary Field Safety Corrective Action.
Root cause tag
labeling and UDI
FDA root cause
Under Investigation by firm
Action
Recall notices were sent 6/29/2016.
Quantity in commerce
544 (2/PACKS)
Distribution
Illinois
Product codes and lots
Lot numbers 914873, 914876, and 914878 of the individual modules (7700RAW), which are contained in Lot number 914867 of the 2/PACK (7700RAW2). Expiration Date JAN 2021.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2846-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2846-2016Class IITerminatedVoluntary: Firm initiated
Z-2847-2016Class IITerminatedVoluntary: Firm initiated