Z-2342-2016Class I

NucliSENS easyMAG Magnetic Silica The NucliSENS easyMAG accessory products are reagents and disposable to be...

bioMerieux, Inc. / initiated 2016-07-08 / Terminated

BioMerieux SA began a recall of NucliSENS easyMAG Magnetic Silica The NucliSENS easyMAG accessory products are reagents and disposable to be used with the bioMerieux extraction systems which... on . FDA classified it as Class I and gives the reason as "Several customer complaints about amplification performance issues when using different batches of MagSil with the NucliSENS easyMAG extraction platform". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-2342-2016
Classification
Class I
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
bioMerieux, Inc.
Product
NucliSENS easyMAG Magnetic Silica The NucliSENS easyMAG accessory products are reagents and disposable to be used with the bioMerieux extraction systems which mention these products in their User Manuals. They enable the automated extraction (purification and concentration) of total nucleic acids (RNA/DNA) from biological samples which are liquid and homogeneous. These products are intended for in vitro diagnostic use by healthcare professionals only.
Product code
LDT
Reason for recall
Several customer complaints about amplification performance issues when using different batches of MagSil with the NucliSENS easyMAG extraction platform.
FDA root cause
Under Investigation by firm
Action
Consignees were notified of the recall by letter on July 18, 2016. The letter informed them of what actions need to be taken if they experience problems. The letter included a reply form to be returned. Subsidiaries and distributors were notified electronically on 7/8/2016.
Quantity in commerce
7,845 units
Distribution
Worldwide Distribution - US Nationwide in the states of: AL, AK, AZ, AR, CA, CO, CT, FL, GA, HI, IL, IN, KS, KY, LA, ME, MD, MA, MI, MN, MO, NJ, NM, NY, NC, OH, OK, OR, PA, RI, SC, TN, TX, UT, VT, VA, WA, WV, WI, and the countries of Angola, Argentina, Austria, Australia, Austria, Botswana, Brazil, Burkina Faso, Cambodia, China, Colombia, Djibouti Antilles, Estonia, Georgia, Germany, Greece, India, Israel, Italy, Kuwait, Latvia, Malaysia, Mexico, Netherlands, Poland, Qatar, Russia, Senegal, Singapore, South Africa, South Korea, Spain, Sweden, Switzerland, Thailand, Turkey, United Kingdom, Zambia, and Zimbabwe
Product codes and lots
Lots - Z017BB1MS, Z017BF1MS, Z017CA1MS, Z017BE1MS, Z017CC1MS, Z017CD1MS, Z017CH1MS, Z017BD1MS, Z017DB1MS, Z017BA1MS, Z017CF1MS, Z017CE1MS, Z017CG1MS, Z017DA1MS, Z017DC1MS, Z017DD1MS, Z017EA1MS, Z017EB1MS, Z017FB1MS, Z017KF1MS, Z017KG1MS, Z017KH1MS

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2342-2016
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2342-2016Class ITerminatedVoluntary: Firm initiated