Z-2663-2016Class II
Infinite 200 PRO The Tecan Infinite 200 PRO is a multifunctional microplate reader with injector option. The...
Tecan U.S. / initiated 2016-07-25 / Terminated / root cause: manufacturing process
Tecan US, Inc. began a recall of Infinite 200 PRO The Tecan Infinite 200 PRO is a multifunctional microplate reader with injector option. The Infinite 200 PRO provides high performance for the... on . FDA classified it as Class II and gives the reason as "The batteries have the potential to overheating, melt or char". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-2663-2016
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Tecan U.S.
- Product
- Infinite 200 PRO The Tecan Infinite 200 PRO is a multifunctional microplate reader with injector option. The Infinite 200 PRO provides high performance for the vast majority of todays microplate applications and research and is robotic compatible. The Infinite 200 PRO has been designed as a general purpose laboratory instrument for professional use, supporting common 6 to 384-well microplates conforming to the ANSI/SBS standards.
- Product code
- JJQ Colorimeter, Photometer, Spectrophotometer For Clinical Use
- Reason for recall
- The batteries have the potential to overheating, melt or char.
- Root cause tag
- manufacturing process
- FDA root cause
- Nonconforming Material/Component
- Action
- Tecan contacted all customers by Safety Announcement, via certified mail starting July 25, 2016. The letter identified the product, the problem, and the action to be taken by the customer. Because affected batteries pose a fire and burn hazard, it is extremely important that customers check whether their battery is affected. Customers were advised to go immediately to the HP Battery Recall website at: http://www.HP.com/go/batteryprogram2016 to check if their battery is affected by this recall. Customers were also advised to complete and return the Customer Response Form at [email protected] or fax it to 919-287-2961. Customers with questions should contact HP at 1-888-202-4320 or Tecan Technical Service's Helpdesk at 800-832-2687, option 1.
- Quantity in commerce
- 27 units
- Distribution
- Worldwide Distribution - US including AK, AL, AR, CA, FL, GA, HI, KY, MA, MD, NC, NY, PA, PR, SC, TN, TX, UT, VA. International account: Canada.
- Product codes and lots
- Instrument Material #30050303, PC Serial numbers: CND5219H0B, Instrument Serial #1208002673; PC Serial numbers: CND44273RW, Instrument Serial #1211001074; PC Serial numbers: CND44273SC, Instrument Serial #1309006773; PC Serial numbers: 2CE3461RNR, Instrument Serial #1311008588; PC Serial numbers: 2CE33625KT, Instrument Serial #1401006356; PC Serial numbers: 2CE33626Q9, Instrument Serial #1403000833; PC Serial numbers: 2CE3461RR3, Instrument Serial #1403003928; PC Serial numbers: 2CE33625M4, Instrument Serial #1403005482; PC Serial numbers: 2CE41503JF, Instrument Serial #1405000420; PC Serial numbers: CND5219H4R, Instrument Serial #1405002510; PC Serial numbers: 2CE42406YJ, Instrument Serial #1406009472; PC Serial numbers: 2CE4220LGP, Instrument Serial #1410002321; PC Serial numbers: 2CE424072G, Instrument Serial #1410004940: PC Serial numbers: 2CE4240DJ7, Instrument Serial #1411008631; PC Serial numbers: 2CE424071M, Instrument Serial #1412005274; PC Serial numbers: CND44273XR, Instrument Serial #1503001536; PC Serial numbers: CND5219H1S, Instrument Serial #1503002986; PC Serial numbers: CND44262KJ, Instrument Serial #1503004890; PC Serial numbers: CND442625D, Instrument Serial #1501008506; PC Serial numbers: CND442627J, Instrument Serial #1501008513; PC Serial numbers: CND44273SB, Instrument Serial #1505009092; PC Serial numbers: CND442626B, Instrument Serial #1509001022; PC Serial numbers: CND5219H11, Instrument Serial #1509008146; PC Serial numbers: CND5219H6D, Instrument Serial #1511009716; PC Serial numbers: 2CE3461RSX, Instrument Serial #1512005211; PC Serial numbers: 2CE3381HT1, Instrument Serial #1601005141 and PC Serial numbers: CND5219H2K, Instrument Serial #1510004918.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2660-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2661-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2662-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2663-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2664-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2665-2016 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2666-2016 | Class II | Terminated | Voluntary: Firm initiated |