Z-0653-2017Class II

COBRA Fusion 50 Ablation System, COBRA Fusion 150 Ablation System, and COBRA Fusion Magnetic Retriever...

AtriCure, Inc. / initiated 2016-09-22 / Terminated / root cause: design

AtriCure, Inc. began a recall of COBRA Fusion 50 Ablation System, COBRA Fusion 150 Ablation System, and COBRA Fusion Magnetic Retriever System. Model Numbers: 700-001, 700-001S, 700-001MI... on . FDA classified it as Class II and gives the reason as "Due to product design and process control, part of the device can separate and remain behind when the device is removed that can potentially cause permanent impairment or damage to body function or structure". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-0653-2017
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
AtriCure, Inc.
Product
COBRA Fusion 50 Ablation System, COBRA Fusion 150 Ablation System, and COBRA Fusion Magnetic Retriever System. Model Numbers: 700-001, 700-001S, 700-001MI, 700-002, and 700-003. Intended to ablate cardiac tissue during cardiac surgery using radiofrequency (RF) energy when connected directly to the Estech Electrosurgical unit (ESU).
Product code
OCL Surgical Device, For Cutting, Coagulation, And/Or Ablation Of Tissue, Including Cardiac Tissue
Reason for recall
Due to product design and process control, part of the device can separate and remain behind when the device is removed that can potentially cause permanent impairment or damage to body function or structure.
Root cause tag
design
FDA root cause
Component design/selection
Action
An Urgent: COBRA Fusion Ablation System Advisory Notification Letter with Acknowledgement Form was sent to all users. The letter described the issue and identified the affected device. Customers were asked to examine their inventory and determine if any affected product was on hand. All users, including those that the device may have been further distributed should be notified with a copy of the letter. Customers are to contact AtriCure customer service at 1-866-349-2342, and select option 6 to return any affected devices. The Device Notification Acknowledgement Form should be completed and returned as soon as possible.
Quantity in commerce
5,263
Distribution
Worldwide Distribution -- USA, in the following states AL, AR, AZ, CA, CO, CT, GA, FL, ID, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, MS, NC, ND, NH, NJ, NV, NY, OH, OK, OR, PA, SC, TN, TX, UT, WA, WI, & VA; and, to the countries of Albania, Australia, Belgium, France, Germany, Ireland, Italy, Norway, Netherlands, Poland, Sweden, Turkey, United Arab Emirates, & United Kingdom.
Product codes and lots
Specifically all lots manufactured prior to February 2016. This information can be identified as the symbol for "date of manufacture" on the product label as: MM-YYYY, e.g. 02-2016 or earlier.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0653-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0653-2017Class IITerminatedVoluntary: Firm initiated