Z-1047-2017Class II

AFX Endovascular AAA System, Endoleak Type IIIA

Endologix LLC / initiated 2016-12-27 / Terminated / root cause: manufacturing process

Endologix began a recall of AFX Endovascular AAA System, Endoleak Type IIIA Product Usage: The AFX Endovascular AAA System is intended for endovascular treatment of patients with... on . FDA classified it as Class II and gives the reason as "Endologix updated the Instructions for Use (IFU) and implemented modifications to the AFX Endovascular AAA System (AFX System)". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-1047-2017
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Endologix LLC
Product
AFX Endovascular AAA System, Endoleak Type IIIA Product Usage: The AFX Endovascular AAA System is intended for endovascular treatment of patients with abdominal aortic or aortoiliac aneurysms (AAA).
Product code
MIH System, Endovascular Graft, Aortic Aneurysm Treatment
Reason for recall
Endologix updated the Instructions for Use (IFU) and implemented modifications to the AFX Endovascular AAA System (AFX System).
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
On 6/2/15, a Dear Physician letter was sent to inform their customers of the 2014 Clinical Update on the Endologix Endovascular Systems for AAA Repair. The letter provided update reports of the cumulative clinical data and information on the Powerlink System and the AFX Endovascular AAA System (AFX System). On January 2016, a Dear Physician letter was sent to customers to inform them of the 2015 Clinical Update covering the Endologix Endovascular Systems for AAA Repair. The letter provided update reports of the cumulative clinical data and commercial experience (i.e., post-market surveillance) of the Powerlink System and the AFX Endovascular AAA system and contains important information and recommendations regarding the continued safe and effective use of these devices. On 12/27/16, a Dear Physician letter will be sent to customers to inform them of the important information related to the AFX Endovascular AAA System (AFX System). The letter provides a series of updates to the Instructions for Use (IFU) and modifications to the product were implemented, including introduction of a graft material processing improvement known as Duraply. Customer are informed of the on-going Endologix investigation that the changes may help prevent the occurrence of Type III endoleaks reported with the AFX device.
Distribution
US and worldwide: Austria, Belgium, Czech Republic, France, Germany, Greece, Ireland, Israel, Italy, Latvia, Luxembourg, Monaco, Netherlands, Poland, Portugal, Spain, Sweden, Switzerland, Turkey, United Kingdom.
Product codes and lots
The correction is not lot specific. It applies to AFX procedures conducted after October 2015

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1047-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1047-2017Class IITerminatedVoluntary: Firm initiated