Z-1892-2017Class III

The TM Ardis Interbody System implant is a convex, straight TLIF or PLIF device for interbody fusion of the...

Zimmer Trabecular Metal Technology, Inc. / initiated 2016-07-07 / Terminated

Zimmer Trabecular Metal Technology, Inc. began a recall of The TM Ardis Interbody System implant is a convex, straight TLIF or PLIF device for interbody fusion of the anterior column of the spine. TM Ardis is designed... on . FDA classified it as Class III and gives the reason as "This field action is being initiated following the firm's discovery of a procedural error in the approval of literature resulting in the undo release of certain content. Information was disseminated to distributors and...". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-1892-2017
Classification
Class III
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer Trabecular Metal Technology, Inc.
Product
The TM Ardis Interbody System implant is a convex, straight TLIF or PLIF device for interbody fusion of the anterior column of the spine. TM Ardis is designed for fusing the adjacent bony surfaces and may be used to replace a disc at one or two contiguous levels in L2-S1. The superior and inferior surfaces of the device are textured to provide increased stability and convex to conform to the vertebral endplates. The device also has two slots on the posterior end to mate with the insertion instrument. The TM Ardis device is wholly comprised of Trabecular Metal Porous Tantalum. Surgical instrumentation for use with the proposed system will be fabricated from surgical grade stainless steel and other applicable materials.
Product code
MAX Intervertebral Fusion Device With Bone Graft, Lumbar
Reason for recall
This field action is being initiated following the firm's discovery of a procedural error in the approval of literature resulting in the undo release of certain content. Information was disseminated to distributors and sales representatives during the 2016 National Sales Meeting held February 17-21, 2016.
FDA root cause
Unknown/Undetermined by firm
Action
Zimmer Biomet sent an Urgent Medical Device Correction Notice dated July 7, 2016, to all consignees on the list requiring them to destroy all literature and notify Zimmer Biomet of others who they have disseminated the material further. Retraining the sales force on the use of the TM Ardis. The details of the strategy are contained within the Draft Recall Strategy attached to the email transmitting this report. For further questions, please call (973) 576-0032.
Quantity in commerce
299 units; 200 brochures
Distribution
Nationwide Distribution
Product codes and lots
n/a

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1892-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1892-2017Class IIITerminatedVoluntary: Firm initiated