Z-1864-2017Class II

Software version 4.44A utilized on the BD MAX System

BD Life Sciences / initiated 2015-07-29 / Terminated / root cause: software

BD LIFE SCIENCES began a recall of Software version 4.44A utilized on the BD MAX System on . FDA classified it as Class II and gives the reason as "The BD MAX System software version 4.44A contains a software anomaly that has the potential to affect some Open System Reagent (OSR) customers utilizing User Defined Protocol (UDP) assays. Customers utilizing only IVD...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-1864-2017
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
BD Life Sciences
Product
Software version 4.44A utilized on the BD MAX System
Product code
NSX
Reason for recall
The BD MAX System software version 4.44A contains a software anomaly that has the potential to affect some Open System Reagent (OSR) customers utilizing User Defined Protocol (UDP) assays. Customers utilizing only IVD assays are not affected. This anomaly may cause the OSR customer system to incorrectly switch the columns of the truth table on the users display. If the user tries to fix their display data, the display will appear correct however, the database may become incorrect, potentially resulting in incorrect results reporting. BD is able to trace the issue to a limited number of instruments that have software version 4.44A installed. Note that the problem only affects customers that are either creating a new UDP with Result Logic or modifying the Result Logic of an existing UDP.
Root cause tag
software
FDA root cause
Software design
Action
BD sent an Urgent Field Corrective Action Recall notification was initiated on July 29, 2015. The customer was initially contacted via a phone call and subsequently provided with a written communication. All US customers were contacted directly by phone and provided the written communication. Global holds were placed on July 21, 2015 and July 24, 2015. For further questions, please call (410) 316-4000.
Quantity in commerce
There are 29 US customers and 5 ex-US regions with a BD MAX System running software version 4.44A.
Distribution
Worldwide Distribution - US Distribution to the states of : CA, CO, FL, IL, MN, MO, MT, NE, NJ, NY, OH, OR, PA, TX, TN, WA, WI., and to the countries of : Canada, Hong Kong, Taiwan, Turkey and Europe. Federal Government Agency sales/distribution centers or foreign countries VA Fort Harrison and VAMC Austin.
Product codes and lots
Catalog number 441916

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1864-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1864-2017Class IITerminatedVoluntary: Firm initiated