Z-2060-2017Class II
Savaria SL-1000 Stairlift
Savaria Concord Lifts, Inc. / initiated 2017-04-12 / Terminated / root cause: design
Savaria Concord Lifts, Inc. began a recall of Savaria SL-1000 Stairlift on . FDA classified it as Class II and gives the reason as "The electrical controller, combined with motor, causes feedback, damaging a component on the control board, starting a fire". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-2060-2017
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Savaria Concord Lifts, Inc.
- Product
- Savaria SL-1000 Stairlift
- Product code
- PCD Powered Stairway Chair Lift
- Reason for recall
- The electrical controller, combined with motor, causes feedback, damaging a component on the control board, starting a fire.
- Root cause tag
- design
- FDA root cause
- Component design/selection
- Action
- The firm sent a letter to dealers dated July 26, 2016. The firm will contact consignees (distributors) via e-mail and phone.
- Quantity in commerce
- 1425 in the United States 734 in Canada
- Distribution
- Distribution in the United States and Canada
- Product codes and lots
- s/n or lot number - Job Number lots 671494 - 672668
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2060-2017 | Class II | Terminated | Voluntary: Firm initiated |