Z-2629-2017Class II
High Frequency Resection Electrodes, endoscope, ac-powered and accessories The electrodes are used for...
OLYMPUS Corporation of the Americas / initiated 2017-04-19 / Terminated
Olympus Corporation of the Americas began a recall of High Frequency Resection Electrodes, endoscope, ac-powered and accessories The electrodes are used for endoscopic diagnosis and treatment in urological and... on . FDA classified it as Class II and gives the reason as "Loop wires breaking at the distal end of the Monopolar HF Resection Electrodes". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-2629-2017
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- OLYMPUS Corporation of the Americas
- Product
- High Frequency Resection Electrodes, endoscope, ac-powered and accessories The electrodes are used for endoscopic diagnosis and treatment in urological and gynecological applications.
- Product code
- GCP Endoscope, Ac-Powered And Accessories
- Reason for recall
- Loop wires breaking at the distal end of the Monopolar HF Resection Electrodes.
- FDA root cause
- Under Investigation by firm
- Action
- Olympus sent an Urgent Medical Device Removal Notice dated April 26, 2017, to affected customers to inform them of the issue. The notice identified the issue, the actions to be taken by the end user. It advised that customers discontinue use of any affected electrodes if found, contact Olympus Customer Care Center and they will provide instructions on how to return the affected product as well get a free replacement. Customer were instructed fax the completed reply from to 484-896-7128. Customer with questions should call 484-896-5688. For questions regarding this recall call 484-896-5000.
- Quantity in commerce
- 1264 units
- Distribution
- Nationwide Distribution
- Product codes and lots
- Model: A22201C - Resection electrode, loop style Lot # 16123P03L001, 16124P03L001, 16131P03L001, 16139P03L001, 16140P03L001, 16144P03L001, 16144P03L002, 16144P03L003, 16155P03L001, 16169P03L001,16173P03L001, 16174P03L001 16174P03L002, 16223P03L001,16224P03L001,16236P03L001 P16X0001, P16X0002,P16X0003,P16X0004,P16Y0001,P16Y0002 P16Y0003,P16Y0004,P16Y0005,P16Y0006,P16Y0007,P16z0001 P16Z0002,P16Z0003,P1710001,P1720001,P1720002 Model: WA22037C - Resection electrode, loop style Lot # 16195P04L001, 16215P04L001, P16Y0001
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2629-2017 | Class II | Terminated | Voluntary: Firm initiated |