Z-3027-2017Class II

1.5T Signa HDx, 3.0T Signa HDx, 1.5T Signa HDxt, 3.0T Signa HDxt, Signa HDi, Signa Vibrant

GE Healthcare / initiated 2017-05-11 / Terminated

GE Medical Systems, LLC began a recall of 1.5T Signa HDx, 3.0T Signa HDx, 1.5T Signa HDxt, 3.0T Signa HDxt, Signa HDi, Signa Vibrant Product Usage: The GE Signa HDx MR system is a whole body magnetic... on . FDA classified it as Class II and gives the reason as "Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-3027-2017
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
GE Healthcare
Product
1.5T Signa HDx, 3.0T Signa HDx, 1.5T Signa HDxt, 3.0T Signa HDxt, Signa HDi, Signa Vibrant Product Usage: The GE Signa HDx MR system is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. The Signa HDx MR system is indicated for use as a diagnostic imaging device to produce axial sagittal, coronal and oblique images, spectroscopic images, and/or spectra, dynamic images of the internal structures and organs of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. The images produced by the Signa eHDx system reflect the spatial distribution of protons (hydrogen nuclei) exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.
Product code
LNH System, Nuclear Magnetic Resonance Imaging
Reason for recall
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
FDA root cause
Mixed-up of materials/components
Action
Consignees received a written recall notice dated 05/17/2017 notifying them of a correction to all units using an Uninterruptable Power Supply. Consignees were instructed not to unplug the unit and to continue normal use. Units with the Eaton 9130 Uninterruptable Power Supply connected to the MR operator console would receive a correction at no charge. This would involve possibly replacing the power cable. GE Representatives will be contacting consignees to arrange corrections. Any questions can be directed to GE Healthcare Service at 1-800-437-1171 or your local service representative.
Quantity in commerce
68 units in total
Distribution
US Nationwide in the states of : AK, CA, CO, CT, DE, FL, IA, IL, IN, KS, KY, LA, MD, MO, ND, NE, NJ, NY, OH, PA, TX, WA, and WI
Product codes and lots
Medical Device Listing No. D117354, D295466, D182389, D102432, D206140, D230310, D269569, D102430, D140572, D188736, D102434, D234841, D196247, D134019, D236543, D006275, D159181, D288890, D229859; Model No. Eaton 9130, 5323286, 5396502-5, 5499460-3, 5499460-6, 5499460-9, 5741000-3, 00840682115971, 5396502-2, 5499460-2, 5741000-2, 00840682115872, 5373011-3, 5396469-3, 5481490-2, 5481500-7, 5499460-7, 5499460-10, 5741000, 00840682103817, 5323286-101, 2377062-61, 2395001, 2395001-2, 2395001-3, 2395001-4, 00840682105699, 840682105378

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-3027-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-3021-2017Class IITerminatedVoluntary: Firm initiated
Z-3022-2017Class IITerminatedVoluntary: Firm initiated
Z-3023-2017Class IITerminatedVoluntary: Firm initiated
Z-3024-2017Class IITerminatedVoluntary: Firm initiated
Z-3025-2017Class IITerminatedVoluntary: Firm initiated
Z-3026-2017Class IITerminatedVoluntary: Firm initiated
Z-3027-2017Class IITerminatedVoluntary: Firm initiated
Z-3028-2017Class IITerminatedVoluntary: Firm initiated
Z-3029-2017Class IITerminatedVoluntary: Firm initiated