Z-0527-2018Class II

Accu2i pMTA Applicator, 29 cm LONG, REF/Catalog # 900-601, Model # (UPN) H7879006010, STERILE --- This is...

Boston Scientific Corporation / initiated 2017-06-05 / Terminated

Angiodynamics, Inc. began a recall of Accu2i pMTA Applicator, 29 cm LONG, REF/Catalog # 900-601, Model # (UPN) H7879006010, STERILE --- This is only for use with a Sulis V Generator, REF 806-10... on . FDA classified it as Class II and gives the reason as "The firm is recalling product that has the potential to not function during use. The product affected by this recall will not deliver the desired microwave energy due to coolant ingress in an electrical connection; this...". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-0527-2018
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Boston Scientific Corporation
Product
Accu2i pMTA Applicator, 29 cm LONG, REF/Catalog # 900-601, Model # (UPN) H7879006010, STERILE --- This is only for use with a Sulis V Generator, REF 806-10. Product Usage: The Acculis Accu2i pMTA Microwave Tissue Ablation Applicator is indicated for the intraoperative coagulation of soft tissue.
Product code
NEY System, Ablation, Microwave And Accessories
Reason for recall
The firm is recalling product that has the potential to not function during use. The product affected by this recall will not deliver the desired microwave energy due to coolant ingress in an electrical connection; this condition results in an error code High Reflective Power displayed on the microwave generator.
FDA root cause
Under Investigation by firm
Action
URGENT VOLUNTARY MEDICAL DEVICE RECALL Letters and Response Forms (dated June 5, 2107) were sent to consignees via FedEx on June 5, 2017. The letter identified the affected product, problem and actions to be taken.
Quantity in commerce
14,353 units in total
Distribution
Worldwide distribution - US Nationwide
Product codes and lots
Lots: 15310414, 15320417, 15340425, 15360433, 15370437, 15380441, 15390445, 15400451, 15470470, 15480472, 16050496, 16070501, 16130515, 16160525, 16190536, 16250558, 16320574, 16330579,  16420606, 16440612, 16460620, 16480630, 16500637, 17010646,  17030654, 17040659, 17070667, 17090672.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0527-2018
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0526-2018Class IITerminatedVoluntary: Firm initiated
Z-0527-2018Class IITerminatedVoluntary: Firm initiated
Z-0528-2018Class IITerminatedVoluntary: Firm initiated
Z-0529-2018Class IITerminatedVoluntary: Firm initiated
Z-0530-2018Class IITerminatedVoluntary: Firm initiated
Z-0531-2018Class IITerminatedVoluntary: Firm initiated