Z-2864-2017Class II

Tomcat Instrument, REF ASY-07379, Hologic Incorporated, automated laboratory sample processing instrument

Hologic, Inc. / initiated 2017-06-27 / Terminated / root cause: software

Hologic, Inc began a recall of Tomcat Instrument, REF ASY-07379, Hologic Incorporated, automated laboratory sample processing instrument on . FDA classified it as Class II and gives the reason as "A Tomcat Instrument software anomaly that causes the pipettor arm to make physical contact with the mucous shelf which could potentially lead to incorrect patient results". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-2864-2017
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Hologic, Inc.
Product
Tomcat Instrument, REF ASY-07379, Hologic Incorporated, automated laboratory sample processing instrument.
Product code
JQW Station, Pipetting And Diluting, For Clinical Use
Reason for recall
A Tomcat Instrument software anomaly that causes the pipettor arm to make physical contact with the mucous shelf which could potentially lead to incorrect patient results.
Root cause tag
software
FDA root cause
Software design
Action
Hologic initiated the recall on Tuesday, June 27, 2017. The method of notification with either: A letter will be provided at a face-to-face meeting with a Hologic representative. Customers will be contacted by phone and electronically sent the letters. The letters will be delivered in one of the following ways: A Hologic representative will hand-deliver the recall letter to the laboratory management. Or Customers will be contacted by phone and electronically sent the letters. The letter states the problem and that a software fix is available. Those with who have the problem will have priority repair.
Quantity in commerce
164 units
Distribution
Worldwide distribution. US Nationwide and countries: BE, CA, CH, ES, FR, GB, IE, IT, JP, LU, NL, SE, SK, and TR.
Product codes and lots
TC00000050,TC00000058,TC00000059,TC00000060,TC00000061,TC00000062,TC00000063,TC00000064,TC00000065,TC00000067,TC00000068,TC00000069,TC00000070,TC00000071,TC00000072,TC00000073,TC00000074,TC00000075,TC00000076,TC00000077,TC00000078,TC00000079TC00000080,TC00000081,TC00000082,TC00000083,TC00000085,TC00000086,TC00000087,TC00000088,TC00000089,TC00000090,TC00000091,TC00000092,TC00000093,TC00000094,TC00000096,TC00000097,TC00000098,TC00000099,TC00000100,TC00000101,TC00000102,TC00000103,TC00000104,TC00000105,TC00000106,TC00000107,TC00000108,TC00000109TC00000110,TC00000111,TC00000112,TC00000113,TC00000114,TC00000115,TC00000116,TC00000117,TC00000118,TC00000119,TC00000120,TC00000121,TC00000123,TC00000124,TC00000125,TC00000126,TC00000127,TC00000128,TC00000129,TC00000130,TC00000131,TC00000132,TC00000133,TC00000134,TC00000136,TC00000137,TC00000138,TC00000139,TC00000140,TC00000141,TC00000142,TC00000143,TC00000144,TC00000145,TC00000146,TC00000147,TC00000148,TC00000149,TC00000150,TC00000151,TC00000152,TC00000153,TC00000154,TC00000155,TC00000156,TC00000157,TC00000158,TC00000159,TC00000160,TC00000161,TC00000162,TC00000163,TC00000164,TC00000165,TC00000166,TC00000167,TC00000168,TC00000170,TC00000171,TC00000172,TC00000173,TC00000174,TC00000175,TC00000177,TC00000178,TC00000179,TC00000181,TC00000182,TC00000183,TC00000184,TC00000185,TC00000187,TC00000188,TC00000189,TC00000190,TC00000191,TC00000192,TC00000193,TC00000195,TC00000197,TC00000198,TC00000199,TC00000200,TC00000201,TC00000202,TC00000203,TC00000204,TC00000206,TC00000207,TC00000208,TC00000209,TC00000210,TC00000211,TC00000212,TC00000213,TC00000214,TC00000215,TC00000227,TC00000236,TC00000242,TC00000249,TC00000254,TC00000263,TC00000264,TC00000266,TC00000270,TC00000273,TC00000274,TC00000280,TC00000283,TC00000284,TC00000285,TC00000289,TC00000291

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2864-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2864-2017Class IITerminatedVoluntary: Firm initiated