Z-2785-2017Class II

SORIN GROUP, SMART PERFUSION PACK, SMA PRIMO2X OPTI PACK, REF 088512900, STERILE EO, Rx Only, 1 EA

LivaNova USA, Inc. / initiated 2017-06-29 / Terminated / root cause: packaging

Sorin Group USA, Inc. began a recall of SORIN GROUP, SMART PERFUSION PACK, SMA PRIMO2X OPTI PACK, REF 088512900, STERILE EO, Rx Only, 1 EA on . FDA classified it as Class II and gives the reason as "Medtronic informed LivaNova that some of their DLP Pressure Disposable Display Sets are packaged in pouches which may have small pinholes (approximately 1mm or less in diameter). The result is a potential sterile...". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.

Recall record

Recall number
Z-2785-2017
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
LivaNova USA, Inc.
Product
SORIN GROUP, SMART PERFUSION PACK, SMA PRIMO2X OPTI PACK, REF 088512900, STERILE EO, Rx Only, 1 EA
Product code
DWE Tubing, Pump, Cardiopulmonary Bypass
Reason for recall
Medtronic informed LivaNova that some of their DLP Pressure Disposable Display Sets are packaged in pouches which may have small pinholes (approximately 1mm or less in diameter). The result is a potential sterile barrier breach in the display sets. These display sets are included with LivaNova Perfusion Tube Sets (PTS) which were then distributed to customers.
Root cause tag
packaging
FDA root cause
Other
Action
The firm initiated their recall verbally on 06/29/2017 and following with letters mailed on 07/13/2017. The actions to be taken by the customer: 1. Notify staff to not use the Medtronic labeled device contained within the LivaNova Perfusion Tube Set packs. 2. If the set is a standalone component within the pack, remove the device upon opening the pack at the time of the procedure. 3. If the device is connected to the circuit, remove the device and attach a new unit upon opening the pack. 4. Identify the Medtronic device with one of the barcode pack labels attached to the lidstock of the LivaNova perfusion pack. 5. Collect the devices for return to LivaNova until all affected perfusion sets have been consumed. In order to assist in controlling inventory, the LivaNova sales representative will have labels available to identify packs containing the affected devices. 6. Contact LivaNova Customer Support at (800) 650-2623 (M-F 8AM to 5PM MT) to arrange for the return of the affected product, and to order equivalent replacement product.
Quantity in commerce
524 units
Distribution
Nationwide
Product codes and lots
Lot Numbers: 1620700048, 1621600063, 1623700039, 1624500038, 1625900047, 1626500084, 1627800066, 1628500062, 1630000040, 1630500055, 1631400035, 1633300052, 1635400049, 1700600038,  1702500069, 1704500039, 1706600107, 1707400082, 1708600072, 1710800102, 1711700034, 1713600045, 1715000038, 1717000046

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2785-2017
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2783-2017Class IITerminatedVoluntary: Firm initiated
Z-2784-2017Class IITerminatedVoluntary: Firm initiated
Z-2785-2017Class IITerminatedVoluntary: Firm initiated
Z-2786-2017Class IITerminatedVoluntary: Firm initiated
Z-2787-2017Class IITerminatedVoluntary: Firm initiated
Z-2788-2017Class IITerminatedVoluntary: Firm initiated
Z-2789-2017Class IITerminatedVoluntary: Firm initiated
Z-2790-2017Class IITerminatedVoluntary: Firm initiated
Z-2791-2017Class IITerminatedVoluntary: Firm initiated
Z-2792-2017Class IITerminatedVoluntary: Firm initiated
Z-2793-2017Class IITerminatedVoluntary: Firm initiated
Z-2794-2017Class IITerminatedVoluntary: Firm initiated
Z-2795-2017Class IITerminatedVoluntary: Firm initiated
Z-2796-2017Class IITerminatedVoluntary: Firm initiated
Z-2797-2017Class IITerminatedVoluntary: Firm initiated
Z-2798-2017Class IITerminatedVoluntary: Firm initiated