Z-0517-2018Class II
PC-1000, PC-1000/Laser1000, Model Numbers 800724-2 & 800724-3
Panoramic Rental Corp. / initiated 2017-07-14 / Terminated / root cause: design
Panoramic Rental Corp. began a recall of PC-1000, PC-1000/Laser1000, Model Numbers 800724-2 & 800724-3 on . FDA classified it as Class II and gives the reason as "The lift motor used to raise and lower the overhead chassis will wear if not properly maintained according to the maintenance schedule". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0517-2018
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Panoramic Rental Corp.
- Product
- PC-1000, PC-1000/Laser1000, Model Numbers 800724-2 & 800724-3
- Product code
- EHD Unit, X-Ray, Extraoral With Timer
- Reason for recall
- The lift motor used to raise and lower the overhead chassis will wear if not properly maintained according to the maintenance schedule.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- On July 14, 2017, Panoramic distributed Urgent Medical Device Correction notices to customers who own and have not taken action as required for the PC-1000 X-ray system machines. This means that your device does not have a critical safety feature that is intended to protect your patients and staff from harm. Customers are encouraged to immediately discontinue use of their machine and follow the instructions in the notice. Customers are encouraged to not resume use of the machine until a certified Panoramic service technician repairs the lift motor. Customers are advised to contact Panoramic to ensure any safety risks associated with the lift motor are identified and addressed. Action Required: (A) If your PC1000 machine is still in service at this location, you must immediately discontinue use and choose one of the following by returning the Acknowledgement Form or contacting the Panoramic Service Team by calling 888-381-2577 Monday through Friday 8 am - 6 pm. 1. An upgraded lift motor assembly at no cost to you; 2. A digital Panoramic rental unit to replace your PC1000, contingent on a signed one year rental contract (subject to availability); or 3. A new digital Panoramic or PanoramicCephalometric unit to replace your PC1000 at a reduced price (starting at $17,995 depending on machine type and subject to availability) (B) If your PC1000 machine is no longer in service or under your control: 4. If the machine is no longer in service, Panoramic will provide free removal of your machine.
- Quantity in commerce
- 13,340 units
- Distribution
- US Nationwide distribution including Puerto Rico
- Product codes and lots
- Serial Numbers: 6001 to 19340
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0517-2018 | Class II | Terminated | Voluntary: Firm initiated |