Medtronic Ascenda(R) Intrathecal Catheter, Models: (a) 8780, UDI: 00643169202122, 00643169783027 (b) 8781...
Medtronic Neuromodulation began a recall of Medtronic Ascenda(R) Intrathecal Catheter, Models: (a) 8780, UDI: 00643169202122, 00643169783027 (b) 8781, UDI: 00643169202139 (c) 8784, UDI: 00643169202153... on . FDA classified it as Class III and gives the reason as "There is a possibility that specific lots of catheters that have recently been distributed may be at risk for an increased potential for kinking at the proximal end where the catheter connects to the drug infusion pump". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-0537-2018
- Classification
- Class III
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Medtronic Neuromodulation
- Product
- Medtronic Ascenda(R) Intrathecal Catheter, Models: (a) 8780, UDI: 00643169202122, 00643169783027 (b) 8781, UDI: 00643169202139 (c) 8784, UDI: 00643169202153 The Ascenda Intrathecal Catheter kits (models 8780, 8781 and 8784) contain parts of an infusion system that delivers drugs to the intrathecal space. The implanted system consists of an implantable infusion pump and an Ascenda catheter. The catheter connects to the pump at the catheter port and enters the intrathecal space.
- Product code
- LKK Pump, Infusion, Implanted, Programmable
- Reason for recall
- There is a possibility that specific lots of catheters that have recently been distributed may be at risk for an increased potential for kinking at the proximal end where the catheter connects to the drug infusion pump.
- FDA root cause
- Other
- Action
- Medtronic on September 21, 2017, initiated a medical device recall and sent the following via mail (with delivery confirmation) to the consignees. In addition to the mailing, Medtronic field representatives may personally visit the accounts to provide the recall notification, assist the customer as necessary with locating and returning affected product(s), and verify that the customer has or will respond to Medtronic with the Customer Confirmation Form. For further questions, please call (800) 707-0933.
- Quantity in commerce
- 194 units
- Distribution
- Nationwide Distribution
- Product codes and lots
- (a) Model 8780: N740471001, N740482002, N740507001, N741669001, N741918005, N742124002, N742180002, N742214002, N743749002, N747547001, N740471002, N740482003, N740507002, N741669002, N742077001, N742124004, N742180003, N742214003, N743749004, N747547003, N740471003, N740482004, N740507003, N741669003, N742077002, N742124005, N742180004, N742214004, N743749005, N747547004, N740471004, N740482005, N740507004, N741669004, N742077003, N742124006, N742180006, N742214005, N743749006, N747547005, N740471005, N740482006, N740507005, N741669005, N742077004, N742143001, N742184003, N742942001, N743773001, N740471006, N740496001, N740507006, N741669006, N742077005, N742143002, N742184004, N742942002, N743773002, N740476001, N740496003, N740508001, N741677001, N742077006, N742143005, N742184005, N742942003, N743773003, N740476002, N740496004, N740508002, N741677002, N742088001, N742143006, N742184006, N742942004, N743773004, N740476004, N740496005, N740508003, N741677004, N742088002, N742151001, N742197001, N742942005, N743773005, N740476006, N740496006, N740508004, N741677006, N742088003, N742158002, N742197002, N742977001, N743800006, N740477001, N740500001, N740508006, N741688001, N742088004, N742158003, N742197003, N742977002, N744024001, N740477002, N740500003, N740511001, N741688002, N742088005, N742158004, N742197004, N742977003, N744024002, N740477003, N740500004, N740511002, N741688003, N742088006, N742158005, N742197005, N742977004, N744024003, N740477004, N740500005, N740511003, N741688004, N742093002, N742158006, N742197006, N742977005, N744024004, N740477005, N740500006, N740511004, N741688005, N742093004, N742172001, N742211001, N743157002, N744024005, N740477006, N740506001, N740511005, N741688006, N742093005, N742172002, N742211002, N743157003, N744024006, N740479003, N740506002, N740540002, N741918001, N742112003, N742172003, N742211003, N743157004, N747546001, N740479004, N740506003, N740540003, N741918002, N742112004, N742172004, N742211004, N743157005, N747546003, N740479005, N740506004, N740540005, N741918003, N742112006, N742172005, N742211005, N743157006, N747546004, N740482001, N740506006, N740540006, N741918004, N742124001, N742180001, N742214001, N743749001, N747546005 (b) Model 8781: N745579001, N745579002, N745579005, N745579006, N746858001 (c) Model 8784: N745557001, N745557002, N745557003, N745557004, N745557005
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0537-2018 | Class III | Terminated | Voluntary: Firm initiated |