Z-0327-2018Class II
EMPOWR Porous Knee System TIBIAL PUNCH, SMALL, REF 801-05-202, NON STERILE, Qty 1 For use in orthopedic...
Encore Medical, LP / initiated 2017-12-12 / Terminated / root cause: design
Encore Medical, Lp began a recall of EMPOWR Porous Knee System TIBIAL PUNCH, SMALL, REF 801-05-202, NON STERILE, Qty 1 For use in orthopedic surgery on . FDA classified it as Class II and gives the reason as "The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0327-2018
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Encore Medical, LP
- Product
- EMPOWR Porous Knee System TIBIAL PUNCH, SMALL, REF 801-05-202, NON STERILE, Qty 1 For use in orthopedic surgery.
- Product code
- JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- The Locking Punch Guide was not sufficiently guiding the large press fit punch, causing the implant to be placed 2-3mm more posterior than intended.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- The field safety notice was disseminated by email on 12/12/2017. The notice stated the following: "DJO Sales Agents Action: Please review the bulletin that is provided with this notice. This bulletin contains new instructions on the use of the Locking Punch Guide and Punch. Please ensure your surgeons are familiar with this information. DJO Surgical then requires that you complete the attached acknowledgment and email it to [email protected]. Please have this form returned by December 15, 2017 Once redesigned guides are available, they will be exchanged through a separate field action."
- Quantity in commerce
- 2 units
- Distribution
- One medical device distributor in California.
- Product codes and lots
- Lot 252564
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0326-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0327-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0328-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0329-2018 | Class II | Terminated | Voluntary: Firm initiated |