Z-0956-2018Class II

Double Flexible Tipped Wire Guide

Cook Incorporated / initiated 2017-10-13 / Terminated / root cause: labeling and UDI

Cook Inc. began a recall of Double Flexible Tipped Wire Guide on . FDA classified it as Class II and gives the reason as "Label does not state that the product is heparin-coated". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-0956-2018
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Cook Incorporated
Product
Double Flexible Tipped Wire Guide
Product code
DQX Wire, Guide, Catheter
Reason for recall
Label does not state that the product is heparin-coated.
Root cause tag
labeling and UDI
FDA root cause
Labeling Change Control
Action
On October 31, 2017 an URGENT MEDICAL DEVICE CORRECTION was issued to customers requesting the following, including a corrective action: Step 1: Determine if your product is included in the affected lot ranges by comparing your lot number to the listing provided. " If your product is not affected, complete the Acknowledgement and Receipt Form. " If your product is affected, proceed to Step 2. Step 2: Remove a Heparin Coated label from the label sheet provided and apply to the top right corner of your affected unit. o If you need additional labels, please contact Stericycle at 855.215.4967. If you would like assistance, representatives are available to support you. To request assistance, please contact Stericycle at 855.215.4967
Quantity in commerce
10,367
Distribution
Nationally
Product codes and lots
Catalog # DTDW-/-BW Affected lots include: F3749839 - F4849938 NS5085893 - NS5827127 F4628078 - F4856722 3763189 - 6106860 F3739663 - F4916737 NS4980257 - NS6098990

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0956-2018
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0947-2018Class IITerminatedVoluntary: Firm initiated
Z-0948-2018Class IITerminatedVoluntary: Firm initiated
Z-0949-2018Class IITerminatedVoluntary: Firm initiated
Z-0950-2018Class IITerminatedVoluntary: Firm initiated
Z-0951-2018Class IITerminatedVoluntary: Firm initiated
Z-0952-2018Class IITerminatedVoluntary: Firm initiated
Z-0953-2018Class IITerminatedVoluntary: Firm initiated
Z-0954-2018Class IITerminatedVoluntary: Firm initiated
Z-0955-2018Class IITerminatedVoluntary: Firm initiated
Z-0956-2018Class IITerminatedVoluntary: Firm initiated
Z-0957-2018Class IITerminatedVoluntary: Firm initiated
Z-0958-2018Class IITerminatedVoluntary: Firm initiated
Z-0959-2018Class IITerminatedVoluntary: Firm initiated
Z-0960-2018Class IITerminatedVoluntary: Firm initiated
Z-0961-2018Class IITerminatedVoluntary: Firm initiated
Z-0962-2018Class IITerminatedVoluntary: Firm initiated
Z-0963-2018Class IITerminatedVoluntary: Firm initiated
Z-0964-2018Class IITerminatedVoluntary: Firm initiated
Z-0965-2018Class IITerminatedVoluntary: Firm initiated
Z-0966-2018Class IITerminatedVoluntary: Firm initiated