Pressure Injectable Two- Lumen Central Venous Catheterization Kit with Blue FlexTip, ARROWg+ard Blue PLUS...
Arrow International Inc began a recall of Pressure Injectable Two- Lumen Central Venous Catheterization Kit with Blue FlexTip, ARROWg+ard Blue PLUS Catheter and Sharps Safety Features. Permits venous... on . FDA classified it as Class II and gives the reason as "Products do not contain the Central Venous Catheter Placement Procedures Note or the Central Line Insertion Checklist, which is a tool intended to guide clinicians in the use of best practices during central line...". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-1164-2018
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Arrow International LLC (subsidiary of Teleflex Incorporated)
- Product
- Pressure Injectable Two- Lumen Central Venous Catheterization Kit with Blue FlexTip, ARROWg+ard Blue PLUS Catheter and Sharps Safety Features. Permits venous access to central circulation.
- Product code
- FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
- Reason for recall
- Products do not contain the Central Venous Catheter Placement Procedures Note or the Central Line Insertion Checklist, which is a tool intended to guide clinicians in the use of best practices during central line insertions.
- Root cause tag
- labeling and UDI
- FDA root cause
- Labeling mix-ups
- Action
- On November 16, 2017, an Urgent Medical Device Notification titled "ARROW PSI and Pressure Injectable Multi-Lumen CVC Kits" was issued to customers informing them of the issue, and urging all to take the following actions: 1. Place a copy of this notification and the enclosed Central Line Insertion Checklist with each unit of affected product currently in your inventory. 2. Complete the enclosed Acknowledgement Form and fax it to 1-855-419-8507, Attn: Customer Service or e-mail to [email protected]. If you have any other questions, feel free to contact your local sales representative or Customer Service at 1-866-246-6990.
- Quantity in commerce
- 18,124 total
- Distribution
- Nationwide Distribution
- Product codes and lots
- ASK-45802-PHMW 13F16K0236
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1158-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1159-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1160-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1161-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1162-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1163-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1164-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1165-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1166-2018 | Class II | Terminated | Voluntary: Firm initiated |