Z-1102-2018Class II
Re-Entry" Malecot Nephrostomy Catheter Set, Product Number: M0064101040, GTIN: 08714729008446 The Malecot...
Boston Scientific Corporation / initiated 2017-12-12 / Terminated
Boston Scientific Corporation began a recall of Re-Entry" Malecot Nephrostomy Catheter Set, Product Number: M0064101040, GTIN: 08714729008446 The Malecot Nephrostomy Catheter Set is intended to establish... on . FDA classified it as Class II and gives the reason as "Certain Malecot Nephrostomy Catheters are breaking at the mid-shaft bond during use". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-1102-2018
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Boston Scientific Corporation
- Product
- Re-Entry" Malecot Nephrostomy Catheter Set, Product Number: M0064101040, GTIN: 08714729008446 The Malecot Nephrostomy Catheter Set is intended to establish percutaneous nephrostomy drainage and is indicated for the following: Diagnostic Indications: " Antegrade pyelography " Pressure/perfusion study (Whitaker test) Therapeutic Indications: " Nephrostomy catheter drainage " Perfusion chemolysis of renal stones " Percutaneous nephrolithotomy " Percutaneous resection and coagulation of urothelial tumors
- Product code
- GBO Catheter, Nephrostomy, General & Plastic Surgery
- Reason for recall
- Certain Malecot Nephrostomy Catheters are breaking at the mid-shaft bond during use.
- FDA root cause
- Under Investigation by firm
- Action
- The firm, Boston Scientific, sent an "Urgent Medical Device Product Removal - Immediate Action Required" letter dated 12/12/2017 to its consignees. The letter described the product, problem and actions to be taken. The consignees were instructed to: identify and remove all affected batches from your inventory; immediately discontinue use of and segregate the affected product, and return it to Boston Scientific. Distributors were notified that this removal is to the customer level and asked to notify any customers who received affected product. Consignees were asked to complete and return the Replay Verification Tracking Form (even if you do not have any product to return) via email: [email protected] or Fax to: Field Action Center at 1-866-213-1806. If you have any questions, your local Sales Representative can answer any questions that you may have regarding this removal or contact Vice President , Regulatory Affairs at 508-683-4398 or email: [email protected] or [email protected].
- Quantity in commerce
- 2224
- Distribution
- Worldwide Distribution: US (nationwide) in the following: AL, AR, AZ, CA, CO, CT, DE, FL, GA, IA, IL, IN, KA, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, ND, NE, NJ, NV, NY, OH, OK, OR, PA, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, including the District of Columbia and Puerto Rico; and countries of: Argentina, Bolivia, Brazil, Canada, Chile, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Mexico, Panama, Peru, Venezuela, Australia, Bangladesh, Botswana, China, Kuwait, Lebanon, Macau, Malaysia, Philippines, Saudi Arabia, Singapore, South Africa, South Korea, Turkey, United Arab Emirates, and Zimbabwe.
- Product codes and lots
- Expiration Date Range: 3/27/2018 9/25/2021; Batch: 16852983 18912864 20404111 16969146 18932466 20458384 16987703 19157072 20491745 17078511 19318043 20517724 17159358 19338399 20567074 17248134 19596298 20567075 17672818 19623064 20593962 17780452 19705478 20658862 17910342 19737920 20682997 17960225 19850692 20735792 17976830 19934631 20769252 18100917 20065714 20830243 18106456 20169834 20884298 18172896 20198263 20909294 18280357 20284828 21027051 18398908 20312727 21101918 18821698 20330766 21181528 18876334
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1099-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1100-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1101-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1102-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1103-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1104-2018 | Class II | Terminated | Voluntary: Firm initiated |