Z-2393-2018Class II

Tibial Nail, Standard T2 Tibia 12x315 mm, Product Number 18221231S

Stryker Corp. / initiated 2018-04-27 / Terminated / root cause: manufacturing process

Stryker GmbH began a recall of Tibial Nail, Standard T2 Tibia 12x315 mm, Product Number 18221231S on . FDA classified it as Class II and gives the reason as "The manufacturer has discovered that potentially out-of-specification products may have left the factory. Non-conforming cannulation of the nails may result in reduced component strength and potentially premature nail...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2393-2018
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Stryker Corp.
Product
Tibial Nail, Standard T2 Tibia 12x315 mm, Product Number 18221231S
Product code
HSB Rod, Fixation, Intramedullary And Accessories
Reason for recall
The manufacturer has discovered that potentially out-of-specification products may have left the factory. Non-conforming cannulation of the nails may result in reduced component strength and potentially premature nail breakage.
Root cause tag
manufacturing process
FDA root cause
Employee error
Action
Urgent Product Recall letters dated 4/27/18 were distributed to customers. The letters instructed customers to perform the following actions: 1. Inform individuals within your organization who need to be aware of this device recall. 2. Immediately check all stock areas and/or operating room storage to determine if any devices from the affected product list are at your facility. Response is required, even though you may not have any physical inventory on site anymore. 3. Quarantine and discontinue use of the recalled devices. 4. Maintain awareness of this notice internally until all required actions have been completed within your facility 5. Inform Stryker if any of the subject devices have been distributed to other organizations. a) Please provide contact details so that Stryker can inform the recipients appropriately. b) If you are a Distributor, note that you are responsible for notifying your affected customers. 6. Branches/Agencies: Return all affected products available at your location to: Stryker Orthopaedics/PFA Product Returns Attn: Distribution Inventory Team 325 Corporate Drive Dock M-East Mahwah, NJ 07430 PR 1774317 Event 6020 7. Hospitals/Branches/Agencies: Complete and sign the enclosed Business Reply Form and fax to 1-888-230-2125 or to Email: [email protected]
Quantity in commerce
12
Distribution
The products were distributed to the following US states: AL, Co, FL, KY, NC, TN, UT, and WA.
Product codes and lots
GTIN 04546540197771; Lot code: K074846

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2393-2018
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2393-2018Class IITerminatedVoluntary: Firm initiated
Z-2394-2018Class IITerminatedVoluntary: Firm initiated
Z-2395-2018Class IITerminatedVoluntary: Firm initiated
Z-2396-2018Class IITerminatedVoluntary: Firm initiated
Z-2397-2018Class IITerminatedVoluntary: Firm initiated
Z-2398-2018Class IITerminatedVoluntary: Firm initiated
Z-2399-2018Class IITerminatedVoluntary: Firm initiated
Z-2400-2018Class IITerminatedVoluntary: Firm initiated
Z-2401-2018Class IITerminatedVoluntary: Firm initiated
Z-2402-2018Class IITerminatedVoluntary: Firm initiated
Z-2403-2018Class IITerminatedVoluntary: Firm initiated
Z-2404-2018Class IITerminatedVoluntary: Firm initiated
Z-2405-2018Class IITerminatedVoluntary: Firm initiated
Z-2406-2018Class IITerminatedVoluntary: Firm initiated
Z-2407-2018Class IITerminatedVoluntary: Firm initiated
Z-2408-2018Class IITerminatedVoluntary: Firm initiated