Z-2468-2018Class II
Fx SOLUTIONS CENTERED HEAD CoCr 50x19, REF 106-5019
Fx Shoulder Solutions SAS / initiated 2018-06-04 / Terminated / root cause: packaging
Fx Solutions began a recall of Fx SOLUTIONS CENTERED HEAD CoCr 50x19, REF 106-5019 Product Usage: Device is designed to produce and deliver proton beam for the treatment of patients with... on . FDA classified it as Class II and gives the reason as "Breach in the external blister of certain lots of Humelock Offset Head 50 X 20 and Centered Head 50 X 19". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.
Recall record
- Recall number
- Z-2468-2018
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Fx Shoulder Solutions SAS
- Product
- Fx SOLUTIONS CENTERED HEAD CoCr 50x19, REF 106-5019 Product Usage: Device is designed to produce and deliver proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation. The PTS may include a fixed small beam treatment room dedicated to the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation localized to the head and neck.
- Product code
- HSD Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
- Reason for recall
- Breach in the external blister of certain lots of Humelock Offset Head 50 X 20 and Centered Head 50 X 19.
- Root cause tag
- packaging
- FDA root cause
- Package design/selection
- Action
- The firm initiated the recall by email on 06/04/2018 in France, on 06/05/2018, to distributors in the US and elsewhere. The distributor (US Agent) sent the notice on to the division agents who store the product. The firm requested return of the units.
- Quantity in commerce
- 131 units
- Distribution
- Worldwide Distribution - US Nationwide and the countries of: France, Argentina, South Africa, Spain, Israel, Germany, Lebanon, Italy, Chile, Belgium, Greece, Mexico, Poland, Hong Kong, Switzerland
- Product codes and lots
- UDI: 03701037300435 Lot Numbers: K238, K240, K689R, K1119, K1120, K1121, K1844, L1730, L1737, L1748, L1756, L1764, L1820, M1042 OUS only: K237, K239
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2468-2018 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2469-2018 | Class II | Terminated | Voluntary: Firm initiated |