510(K) CLEARANCES 67 ▼8RECALLS POSTED 26CLASS I 2PMA DECISIONS 40 ▼14WEEK ENDING / FDA DATA AS OF
Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-2515-2018Class II

Tri-Staple 2.0 Curved Tip Intelligent Reload for use with Signia stapling system 45 mm Vascular/Medium, Item...

Medtronic, Inc. / initiated 2018-05-22 / Open, Classified / root cause: manufacturing process

COVIDIEN MEDTRONIC began a recall of Tri-Staple 2.0 Curved Tip Intelligent Reload for use with Signia stapling system 45 mm Vascular/Medium, Item Code SIG45ACTAVM on . FDA classified it as Class II and gives the reason as "Device may be missing a sled component. The sled component is responsible for staple deployment. This may result in failure to form a staple line when tissue is divided, leading to bleeding or leakage of luminal contents". As of , the recall status on record is Open, Classified, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2515-2018
Classification
Class II
Status
Open, Classified
Initiated
Posted
Recalling firm
Medtronic, Inc.
Product
Tri-Staple 2.0 Curved Tip Intelligent Reload for use with Signia stapling system 45 mm Vascular/Medium, Item Code SIG45ACTAVM
Product code
GDW Staple, Implantable
Reason for recall
Device may be missing a sled component. The sled component is responsible for staple deployment. This may result in failure to form a staple line when tissue is divided, leading to bleeding or leakage of luminal contents.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
On May 22, 2018, all U.S. consignees received an UPDATED URGENT MEDICAL DEVICE RECALL and RETURN FORM notice via Federal Express or certified. The initial notice was sent to impacted customers on April 26, 2018. Customers are advised to take the following required actions: 1. Immediately discontinue use, and quarantine affected products listed 2. Return affected product as indicated. 3. Complete the Recalled Product Return Form even if you do not have inventory and submit by either method below: * Product purchased directly from Medtronic: [email protected] or fax to (800) 895-6140. *Product purchased through distributor: [email protected] or fax it to (203) 492-7719.
Distribution
Nationwide U.S.A. Internationally to: Albania, Algeria, Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Guadeloupe, Hungary, Iceland, Ireland, Israel, Italy, Ivory Coast, Jordan, Kazakhstan, Kuwait, Latvia, Lebanon, Luxembourg, Macedonia, Malta, Martinique, Moldova, Morocco, Namibia, Netherlands, New Caledonia, Norway, Pakistan, Poland, Portugal, Reunion, Romania, Russian federation, Saudi Arabia, Serbia, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Tunisia, Turkey, United Arab Emirates & United Kingdom
Product codes and lots
N7L1049X & N7M0723X

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2515-2018
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2503-2018Class IIOngoingVoluntary: Firm initiated
Z-2504-2018Class IIOngoingVoluntary: Firm initiated
Z-2505-2018Class IIOngoingVoluntary: Firm initiated
Z-2506-2018Class IIOngoingVoluntary: Firm initiated
Z-2507-2018Class IIOngoingVoluntary: Firm initiated
Z-2508-2018Class IIOngoingVoluntary: Firm initiated
Z-2509-2018Class IIOngoingVoluntary: Firm initiated
Z-2510-2018Class IIOngoingVoluntary: Firm initiated
Z-2511-2018Class IIOngoingVoluntary: Firm initiated
Z-2512-2018Class IIOngoingVoluntary: Firm initiated
Z-2513-2018Class IIOngoingVoluntary: Firm initiated
Z-2514-2018Class IIOngoingVoluntary: Firm initiated
Z-2515-2018Class IIOngoingVoluntary: Firm initiated
Z-2516-2018Class IIOngoingVoluntary: Firm initiated