Z-2659-2018Class II

Leica M530 OHX Microscope System Supplied with 100 - 120 Vac

Leica Microsystems, Inc. / initiated 2018-06-25 / Terminated / root cause: design

Leica Microsystems, Inc. began a recall of Leica M530 OHX Microscope System Supplied with 100 - 120 Vac on . FDA classified it as Class II and gives the reason as "Recall is due to a design weakness of the power insert module". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-2659-2018
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Leica Microsystems, Inc.
Product
Leica M530 OHX Microscope System Supplied with 100 - 120 Vac.
Reason for recall
Recall is due to a design weakness of the power insert module.
Root cause tag
design
FDA root cause
Device Design
Action
Leica Microsystems notified customers on about 06/25/2018 via URGENT FIELD SAFETY NOTICE letter. Instructions included advising customers of the issue, informing them that Leica Microsystems representative will contact them to arrange the fiel update to the device, distribute the recall notification to all individuals that should be aware of the recall or if the device was further distributed and a response form was provided to complete and return. The notification letter also instructed customers to report any anomalies with the system to Leica Microsystems if they occur prior to the correction being made and to ensure a functional check is performed prior to each surgery as described in the user manual.
Quantity in commerce
123 devices total
Distribution
United States distribution: AR, AZ, CA, CO, CT, DE, FL, IL, IN, KS, KY, LA, MO, NJ, NY, NV, OH, OR, PA, TX, UT, PR. International distribution to Japan, Brazil, Columbia, Ecuador, Mexico, Taiwan
Product codes and lots
US: 90116001, 30118001, 51215001, 201117001, 30916001, 270216001, 100917001, 31117001, 00817001, 0316001, 31217001, 180118001, 200218001, 151217001, 21217001, 21214001, 80218001, 170118001, 01017002, 101017001, 170915001, 150117001, 150217001, 291117001, 260517001, 300915001, 0318001, 30318001, 100915001, 310717001, 140716001, 50516001, 281116001, 300517001, 0316001, 30115001, 200617001, 190117001, 170117001, 241217001, 261217001, 271217001, 90118001, 0617001, 250118001, 280115001, 191015001, 81117001, 150617001, 120417001, 140917001, 10318001, 140417001, 250717001, 80518001, 160616001, 170417001, 150417001, 11116001, 91017001, 81117002, 281117001, 20218001, 300118001, 131015001, 140318001, 110516001, 00318001, 160118001, 30518001, 200316001, 120917001, 210118001, 310717001, 30218001, 1217001, 190617001, 130617001, 280817001, 80317001, 310817001, 10917001, 60317001, 60218001, 80917001 230318001, 170318001;   Puerto Rico: 241216001, 261216001;   JAPAN: 140717001,171017001, 211117001, 291217001, 290118001, 210218001, 280218001, 020318001, 120318001, 160318001;   BRAZIL: 120416001, 220917001, 311017001, 70118001, 70318001;   COLOMBIA: 60517001;   ECUADOR: 170316001, 231216001, 190917001;   MEXICO: 31215001, 130117001, 91217001;   TAIWAN: 190815001, 220317001, 190317001, 40517001, 210717001, 210717002, 211217001

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2659-2018
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2659-2018Class IITerminatedVoluntary: Firm initiated