Z-2951-2018Class II

Haemonetics OrthoPAT System-OPAT QuickConnect Reservoirs

Haemonetics Corporation / initiated 2018-07-13 / Terminated / root cause: manufacturing process

Haemonetics Corporation began a recall of Haemonetics OrthoPAT System-OPAT QuickConnect Reservoirs. Product Code: OPT-R-1000 The OrthoPAT orthopedic perioperative autotransfusion system indicated for... on . FDA classified it as Class II and gives the reason as "OrthoPAT reservoirs are missing the cannula inside the reservoirs. The absence of this cannula prevents the emptying of blood from the reservoirs. The inability to empty the reservoir means that the collected blood...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2951-2018
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Haemonetics Corporation
Product
Haemonetics OrthoPAT System-OPAT QuickConnect Reservoirs. Product Code: OPT-R-1000 The OrthoPAT orthopedic perioperative autotransfusion system indicated for use to salvage RBCs from blood lost intraoperatively and postoperatively during surgical procedures
Product code
CAC Apparatus, Autotransfusion
Reason for recall
OrthoPAT reservoirs are missing the cannula inside the reservoirs. The absence of this cannula prevents the emptying of blood from the reservoirs. The inability to empty the reservoir means that the collected blood cannot be processed.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
The firm, Haemonetics, notified customers by an email titled "URGENT: MEDICAL DEVICE RECALL" on July 13, 2018 . The email described the product, problem, and actions to be taken. The customers were instructed to inspect product for defect and return units of the affected lots for replacement with non-affected units; complete the attached customer acknowledgement form via FAX TO +1-781-356-3558 OR SCAN AND E-MAIL TO: [email protected]. You can contact your local customer service representative at: North America 1.800.537.2802 or email:[email protected].
Quantity in commerce
348 units
Distribution
US Nationwide Distribution
Product codes and lots
Lot # 1117066

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2951-2018
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2950-2018Class IITerminatedVoluntary: Firm initiated
Z-2951-2018Class IITerminatedVoluntary: Firm initiated