Z-0355-2019Class III

Software Package, Sorting-Drive 4.2.1 User Kit for Windows XP and Windows 10, Part No. B95347, Manufactured...

Siemens Healthcare Diagnostics Inc. / initiated 2018-05-24 / Terminated / root cause: software

Beckman Coulter Inc. began a recall of Software Package, Sorting-Drive 4.2.1 User Kit for Windows XP and Windows 10, Part No. B95347, Manufactured by: Beckman Coulter Biomedical GmbH The... on . FDA classified it as Class III and gives the reason as "Sorting-Drive software version 4.2 (released in October 2015) introduced a new option which included the Sorting-Drive Client that is used for manual printing of barcodes; version 4.2 was replaced by 4.2.1 (they both...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-0355-2019
Classification
Class III
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Siemens Healthcare Diagnostics Inc.
Product
Software Package, Sorting-Drive 4.2.1 User Kit for Windows XP and Windows 10, Part No. B95347, Manufactured by: Beckman Coulter Biomedical GmbH The Sorting-Drive itself is an optional software to be used with the Automate 2500 Family of products. . The Sorting-Drive 4.2.1 User Kit includes the Sorting-Drive Client software application that includes an option for manual printing of barcodes for sample tubes; version 4.2 was replaced by version 4.2.1 (they both contain the same option for manual barcode printing). This function is primarily used to copy an existing barcode ID to replace the label of an individual sample tube because the original label is deteriorated.
Product code
JQP Calculator/Data Processing Module, For Clinical Use
Reason for recall
Sorting-Drive software version 4.2 (released in October 2015) introduced a new option which included the Sorting-Drive Client that is used for manual printing of barcodes; version 4.2 was replaced by 4.2.1 (they both contain the same option for manual barcode printing). When printing consecutively numbered tube labels using this optional Barcode Counter function, the system incorrectly converts numbers with consecutive multiple zeroes in the middle, potentially leading to wrong barcode IDs.The firm reports this does not affect automated label creation or reprinting of individual labels and that no other system functions are affected.
Root cause tag
software
FDA root cause
Software change control
Action
On 6/4/2018 Beckman Coulter (BEC) reported that the issue will be corrected via a field modification performed by Field Service. BEC reported that they do not intend to send a customer letter for this issue.US customers can contact the Technical Support Troubleshooting Hotline at (800) 854-3633.
Quantity in commerce
54
Distribution
Worldwide Distribution: US (nationwide) and countries of: Algeria, Argentina, Austria, Belgium, Brazil, Chile, China, Czech Republic, Denmark ,France, Germany, Greece ,Hong Kong, India, Ireland, Israel, Italy ,Republic of Korea, Lebanon, Lithuania ,Malaysia, Netherlands, Poland, Portugal , Qatar, Romania, Russian Federation, Saudi Arabia ,South Africa , Spain, Sweden, Taiwan, Turkey , and United Kingdom.
Product codes and lots
v4.2.1 (and 4.2, discontinued)

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0355-2019
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0353-2019Class IIITerminatedVoluntary: Firm initiated
Z-0354-2019Class IIITerminatedVoluntary: Firm initiated
Z-0355-2019Class IIITerminatedVoluntary: Firm initiated
Z-0356-2019Class IIITerminatedVoluntary: Firm initiated
Z-0357-2019Class IIITerminatedVoluntary: Firm initiated
Z-0358-2019Class IIITerminatedVoluntary: Firm initiated
Z-0359-2019Class IIITerminatedVoluntary: Firm initiated